Soyer BMS-9 Operating Instructions Manual page 51

Stud welding device, guns
Table of Contents

Advertisement

Code
Description
E06
Error in the welding gun
E07
Short-circuit in the magnetic circuit
66
No valid key combination pressed
99
No valid key combination pressed
Notes on error messages
• In case of errors E01 to E04, E06 and E07, the device switches to malfunction.
Welding is no longer possible. The device can only be recommissioned when it is
switched off and then switched on again.
• In the event of error code E05, excess temperature, the welding device cannot be used
until the displayed error message disappears.
• If the device operates with reduced charging current due to high internal temperatures,
the "Malfunction" LED flashes.
Possible cause
• Non-permissible welding gun
• Welding gun incorrectly wired
• Wrong adapter on the gun cable
Defective gun cable or magnetic coil.
Wrong keys or keys not correctly pressed. Error
reset by switching the device off and then on again.
Wrong keys or keys not correctly pressed. Error
reset by switching the device off and then on again.
Operating instructions Soyer Bolzenschweißtechnik
51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bms-9vPs-9Ps-9kPs-1k

Table of Contents