Handling
The machine is for sucking and separating dry, not combustive dust with limit value of
explosion >0.1mg/m
3
.
The motor is started by the switch. Dust laden air is then sucked through the inlet valve at
high speed via the suction hose. The air is slowed down by the cyclone and coarse dust
particles are separated out, partly by centrifugal force and partly by gravity. Air and finer
particles then pass through the tube filter where separation is made. The machine is designed
for filter cleaning by reverse air pulse.
The separated dust accumulates in the cyclone until the machine is switched off, when it drops
through the bottom flap into the plastic bag.
Using
Before using must the user be educated in handling the vacuum cleaner and the hazardous
dust.
Connect the electric plug to an outlet with correct voltage (see the designation plate).
From time to time the filter must be cleaned. This must be done before changing the plastic
bag. Even appropriate when the working is completed or when there is poor suction.
Procedure: Unplug the hose so that the inlet will be covered. Cover the intake of the
overpressure valve (placed between the two hoses connecting the main tank the cover for the
micro filters), let the machine build up vacuum for a few seconds then quickly push down on
the top handle and release it slowly. Repeat the procedures 5-10 times. If suction remains
poor, the filter should be replaced.
The plastic bag may only be replaced after cleaning the filter.
The plastic bag must be tied up after removing.
Only use original parts.
Change of filter
Risk of dust dispersion - Personal safety equipment
Health impairing dust can be spread during change of filter. Accordingly, the user should wear
protective glasses, protective gloves, and a breathing mask conforming to protection class
FFP2.
Shut off the machine and pull the plug out of the socket.
Main filter
Loosen the two latches between the tank and the lower cykon. Loosen the two latches at the
hose connection between the tank and the absolute filter cover. Rotate the tank foreword.
Rotate the filter plate counter clock vice 10 deg and lift filter and holder gently up side down
and draw a plastic bag over the filter unit. Lift the filter gently and pinch up the bag by hand
and then tie the bag up. This bag must be taken care of in a proper way.
Insert a new complete filter package in reversed order. Only original filter may be used.