26
Operation Section
Lifting and Storage
General Items
If the lubricating oil filler is installed on the rocker
cover, remove the filler cap. If the lubricating oil filler
cap is not installed on the rocker cover, remove
the rocker cover. Spray 1762811 POWERPART
Lay-Up 2 around the rocker shaft assembly.
Replace the filler cap or the rocker cover.
Seal the vent of the fuel tank or the fuel filler cap
with waterproof tape.
Remove the alternator drive belts and put the drive
belts into storage.
In order to prevent corrosion, spray the engine with
1734115 POWERPART Lay-Up 3. Do not spray
the area inside the alternator.
When the engine protection has been completed in
accordance with these instructions, this ensures that
no corrosion will occur. Perkins are not responsible
for damage which may occur when an engine is in
storage after a period in service.
Your Perkins dealer or your Perkins distributor can
assist in preparing the engine for extended storage
periods.