Visual Check Of The Exhaust After-Treatment System For Damage, Leaks - Manitowoc GHC75 Maintenance Instructions Manual

Telescopic crane
Hide thumbs Also See for GHC75:
Table of Contents

Advertisement

Crane Care
Personnel
Service Technician
Change the DEF disposal module
return filter
Personnel
Service Technician
Change the DEF disposal module
input filter
5.10.2

Visual check of the exhaust after-treatment system for damage, leaks

Personnel
Service Technician
The machine operator
21.12.2017
Exhaust after-treatment system > Visual check of the exhaust after-treatment system for damage, leaks
Interval
Particular interval: as required
F & Operating manual, Chapter: Appendix.
Interval
Particular interval: as required
Protective equipment:
Materials:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Interval
Every 500 OH
Once every 250 OH / approx. 4-6 weeks after commissioning
Preliminary
GHC75 Telescopic crane
Protective clothing
n
Chemical-resistant protective gloves
n
Safety shoes
n
Safety goggles
n
Warm water
n
Park the machine.
Secure the machine against being restarted without authori-
zation.
Open the left service door.
Separate the hose connection from the DEF disposal
module.
Remove the input filter.
Rinse the input filter through with warm water.
Place the input filter back in the hose connection.
Connect the hose connection with the DEF disposal module.
Close the left service door.
Diesel engine service
55