Crane Care
5.3 Changing the engine oil and oil filter
5.4 Air filter
5.4.1 Air filter, general information
L WARNING
NOTICE
SENCON symbol air filter
21.12.2017
Pull out oil dipstick ( 1), and wipe it off with a clean, lint-free
5.
cloth.
Insert oil dipstick up to stop and pull out again.
6.
7.
Check oil level:
The oil level must be between the lower marking (MIN) and
the upper marking (MAX).
If necessary, top up engine oil via the filler neck (2), as speci-
8.
fied in the operating manual provided by the engine manufac-
turer.
Warm up engine.
1.
Park the machine in horizontal position.
2.
Open rear right maintenance door. Remove lower cover.
3.
Change engine oil and oil filter in accordance with the
4.
instructions in the engine manufacturer's operating manual.
Check oil level:
5.
The oil level must be between the lower marking (MIN) and
the upper marking (MAX).
If necessary top up engine oil as specified in the operating
6.
manual provided by the engine manufacturer.
Risk of burns from unsuitable cleaning agents.
Persons suffer burn injuries when cleaning the air filter with
hot or flammable cleaning agents.
–
Never use gasoline, soap or hot liquids to clean the air
filter.
–
Only clean the air filter when the engine is shut off and
cooled down.
Risk of engine damage when cleaning with compressed air.
When cleaning the interior of the housing with compressed
air, contaminants get into the engine.
–
Never use compressed air to clean the interior of the
housing.
The condition of the air filter is monitored by the SENCON. When
contaminated, the SENCON displays the following icon: