Foxy
R1 and Foxy
R2 Fraction Collectors
Appendix A Icon Glossary and Menu Charts
Table A-1 Touch screen display icons (Continued)
Icon
Description
Touch the Ethernet Port icon to open a screen
from which you can configure TCP/IP communi-
cation settings and view the MAC address.
Touch the Inject icon to open a screen from which
you can select the restart action for each injec-
tion.
Restarts can be initiated by a user-specified Time
or an Inject signal from an external device. When
using one of the Inject options, the fraction collec-
tor waits for the first restart event before starting
the method. The touch screen Play icon will alter-
nate with the Inject icon while waiting. After the
injection, touch the Play icon to continue with the
method. Timed restarts occur without interven-
tion.
When a restart occurs, the collection pattern can
return to the first tube of the previous run to Over-
lay multiple fractions from a repeated sample.
Alternatively, a restart can start at the Next tube,
or Skip a tube to separate the runs.
Touch the Pump Control icon to access the set-
tings to control the output at pin 2 of the Pump
connector. This signal can be used to pause the
pump operation during tube advances.
The icon with the "1" (left) indicates that the frac-
tion collector will not send a pause signal from pin
2. In this state, the external pump will continue to
operate during tube changes. The icon with the
"0" indicates that the fraction collector will send a
pause signal from pin 2.
Touch the Analog Peak setting icon to view a list
of voltage ranges for the peak input. When using
this feature, set the analog peak voltage scale to
the range of the detector signal.
Touch the Information icon to display Model num-
ber and hardware/firmware revisions.
Touch the Drop icon to collect fractions based on
the number of drops collected. Touching this icon
opens a screen from which you can set the delay
volume (as a number of drops) and the number of
drops to collect before performing a tube
advance. If selected, the display shows a border
around this icon.
Touch the Time icon to collect fractions based on
time. Touching this icon opens a screen from
which you can set the delay volume (as a time
interval) and the time duration of each fraction. If
selected, the display shows a border around this
icon.