Uploading And Downloading Of Parameters (Upload/Download) - ABB DCS 600 MultiDrive Operating Instructions Manual

Thyristor power converter
Hide thumbs Also See for DCS 600 MultiDrive:
Table of Contents

Advertisement

3.9 Uploading and Downloading of Parameters (UPLOAD/DOWNLOAD)

FUNC
DCS 600 Operating Instructions
CAUTION!
The drive must be in standstill condition with given
STOP command (controllers blocked, power section
disconnected from the network) when UPLOAD/
DOWNLOAD function is selected.
The upload and download function is operative for
groups 10...97
8‚‡…‚yÃ
Qhry
CDP 312
83/2$'
FPROM
'2:1/2$'
UPLOAD will copy all parameters, which are different to default,
from the RAM memory of the SDCS-AMC-DC board to the FPROM
memory of the Control Panel CDP 312.
Before a DOWNLOAD is started the factory-set values (default
values) should be available within the RAM memory of the SDCS-
AMC-DC board. Factory-set values are always available in the
FPROM memory of this board and they can be called by means of
APPLIC_RESTORE parameter 99.09 with the exception of the
group 99. Parameter 99.11 APPLICATION MACRO has to be set
to FACTORY.
The exceptional group has to be checked and if necessary,
changed by manual setting. Instead of this a saved default pa-
rameter set can be loaded by DRIVES WINDOW.
The DOWNLOAD will copy all values stored in the FPROM memory
of the CDP 312 to the RAM memory of the SDCS-AMC-DC board.
Note: For reasons of safety the DOWNLOAD function will only
operate if "LOCAL mode" of the Control Panel CDP 312
is selected!
Chapter 3 - Handling of Control Panel CDP 312
98TÃ%
SDCS-CON-2
SDCS-AMC-DC
FPROM
Actual
Factory
User 1
User 2
Auto-
99.11 =
matically
Factory
RAM
Start
99.9 = Yes
RAM
FPROM
FPROM = FLASH-PROM
RAM = Random Access Memory
Only required for
changed unit-(type-)
dependent values:
[P 15.02] = 22
3 - 11
IV F

Hide quick links:

Advertisement