Start Mode - ABB DCS 600 MultiDrive Operating Instructions Manual

Thyristor power converter
Hide thumbs Also See for DCS 600 MultiDrive:
Table of Contents

Advertisement

Chapter 3 - Handling of Control Panel CDP 312

3.2 Start Mode

3 - 2
IV F
Note: The CDP 312 can be connected to the drive without discon-
necting the auxiliary power!
When the
is connected and power is applied to the elec-
CDP 312
tronics, the display will show:
1. Name and Software version of the Control Panel; an increasing
number of points (row) in the lower line will show, that data
from the Software used with DCS 600 are loaded. If this row
is repeated permanently, it will not be possible to load data as
(for example) there is no correct running of the Software or the
SDCS-AMC-DC board is missing.
-.: :+8/6

2. ID number and number of drives connected to the link.
.-=

3.8?7,/<
3. Afterwards the display will change over to the Actual Signal
Display Mode. Now the selected values are shown here.
4. If a fault or alarm is effective, the corresponding (signal) display
will appear after item 3.
The following message is displayed if the CDP 312 is not able to
communicate with the drive:
0+?6>
89 -977?83-+>398
• The drive is not present on the link. This is the case if the drive
stops communicating.
• The link does not operate because of a hardware malfunction or
a cabling fault.
Action: Disconnect the
drive. Hereby the
Mode once again!
@

89 -977?83-+>398 EbG
EbG

The CDP is not active for 10 s

The drive is not active for 10 s

No data set received for 2 s

Bus administrator is offline
and connect it again to the
CDP 312
will be forced to the Start
CDP 312
DCS 600 Operating Instructions