DCS 600 and Profibus
Hardware
DCS 600
NPBA02
Cable
Associated publications
DCS 600
Profibus
Software settings
DCS 600
Drive
Parameter
51.01
51.02
51.03
51.04
51.05
51.06
51.07
51.08
Note: After change of Parameters Group 51 switch OFF and ON the DCS 600 and the
Fieldbus adapter!
DCS 600 Operating Instructions
SDCS-AMC-DC Classic board
Software V2.2
length 0.2 ... 10 m
Technical Data
Software Description
DC Converter Fieldbus
Database
NPBA
Database
Parameter
Default connected
parameters
Fieldbus
Parameter Name
Par. No.
1
MODULE TYPE
2
PROFIBUS MODE
3
DRIVE NUMBER
4
BIT RATE SELECT
PROFIBUS
5
DATA SET PAIRS
6
DATA SET OFFSET
7
CUT-OFF TIMEOUT
8
COM PROFILE
To be continued!
plastic optical fibre
3ADW000054R0301
3ADW000076R0401
3ADW000097R0101
GLOBAL\DEIND\DEIND051.NSF
3AFY58995789R0125
GLOBAL\FIDRI\FIDRI002.NSF
98.02
=
70.01
=
70.02
=
70.20
=
Main control word
Speed reference
Main status word
Motor speed
Select
PROFIBUS
DP-PPO1 or DP-PPO2
2 to 126
9.6, 19.2, 93.75, 187.5, 500 KBIT;
1.5 MBIT; AUTO
4 { 1, 3, 5, 7 sent to drive}
{ 2, 4, 6, 8 received from drive}
0
0 to 255
0
Chapter 2 - Start-Up Instructions
ABB Lampertheim
ABB Lampertheim
ABB Lampertheim
(not on database)
ABB Helsinki
2 (FIELDBUS)
1
Optical power/cable length
(use default)
1
(data set 1/1)
(data set 1/2)
(data set 2/1)
(data set 2/2)
= Self-adjustment while switching on
IV F
2 - 29