Fault Signals Referring To The Sdcs-Amc-Dc Board - ABB DCS 600 MultiDrive Operating Instructions Manual

Thyristor power converter
Hide thumbs Also See for DCS 600 MultiDrive:
Table of Contents

Advertisement

Chapter 4 - Signals and Troubleshooting

Fault Signals referring to the SDCS-AMC-DC board

Code
Text on
seven
LCD of control panel
segm.
CDP 312
Display
(or DRIVES WINDOW)
 *)
RESET FAULT
 *)
SYSTEM FAULT
 *)
CON COMMUNIC
 *)
CH0 COMMUN
*)
No Fault Code available on seven segment display!
4 - 10
IV F
Definition /
Action
RESET of all faults which can be acknowl-
edged
Fault of the SDCS-AMC-DC board
Fault of the operating system.
Communication fault between the SDCS-AMC-
DC board and the SDCS-CON-2 board
Communication fault with fieldbus,
APC or fieldbus adapters
this signal has to be effective only as
If
an alarm (warning) signal, the mode of
functioning can be changed by setting
the parameter
CH0_COM_LOSS_CTRL
[P 70.05].
Check: - Optical fibre cable connections;
- APC, PLC and
for operation?
s ready
adapter
DCS 600 Operating Instructions
Status
Remark
signal
(FAULT_WORD_
1/2/3)
9.06
bit 7
9.06 bit 10
Can
not be
reset

Hide quick links: