dummyhead
dummyhead
OIL ALERT UNIT INSPECTION
Remove the oil alert unit
Check the continuity between the terminals, and oil
alert unit body.
Use a following range of recommended tester.
• TH-5H (KOWA): R x 100 range
• SP-15D (SANWA): kΩ range
Read the tester manufacturer's operation instructions
carefully before operating the tester. Follow the
instructions of the Service Manual. Be sure the tester's
battery is fully charged, and check the meter before
using the tester.
(–)
(page
7-5).
(+)
Bl [1]
Y [2]
Bl [1]
–
0.5 – 10
Y[2]
0.5 – 10
–
Body [3]
[1]
Unit: kΩ
Body [3]
–
IGNITION SYSTEM
[2]
[3]
7-9