5.

Technical data

Current
Operating mode pump
Delivery rate at 0.3 bar backwater pressure
Mains voltage (primary)
Standby power
Power
Potential-free contact (accessory)
Application temperature control unit
Protective rating
Protective class
Protective rating (complete system without control unit)
Connection type
Cable length
Required fuse protection
battery, 9V type MN, Duracell, order no. 197-081 *2)
Alternatively, the following can be used (9V, ANSI 1604): Energizer Alcaline 522, Ultralife U9VLBP
5.1.

Shortening or lengthening the pump/probe connection cable

Extensions to be ordered (length 10m)
• Art. # 80889 Probe
• Art. # 80890 Motor
• Art. # 80891 Pump
The maximum cable length of 30 m must not
per hour.
If a connection cable is shortened, the wires must
be placed as shown in Fig. [30].
TECHNICAL DATA
34/120
4.9 A /cosɸ = 1
S3 - 30% at 35°C
Q = 2.8 l/s
230 V AC 50 Hz (plug)
approx. 2.5 W
1200 W max.
42 V DC / 0.5A
0°C to + 50°C
IP 54 (control unit),
IP 68, 0.3 bar (pump, probe) 24 h
I
IP 68 with max. 3 mWS and max. 24 h
Safety plug
1.4m
C 16 A 1-pole
2 x
1.
3.
[16]
2.