SiteTecht Parameter
Analog Resistive Input Low Shutdown Delay
Analog Resistive Input High Shutdown Delay
Analog Resistive Input Low Warning Limit
Analog Resistive Input Critically Low Warning Limit
Analog Resistive Input Low Shutdown Limit
Analog Resistive Input High Warning Limit
Analog Resistive Input Critically High Warning Limit
Analog Resistive Input High Shutdown Limit
Analog Resistive Input Deadband
Analog Resistive Input Relative Upper Range Limit
Analog Resistive Input Relative Lower Range Limit
Analog Resistive Input Relative Range Limit Deadband
Analog Resistive Input Relative Range High Limit Inhibit
Time
Analog Resistive Input Relative Range Low Limit Inhibit
Time
Analog Resistive Input Relative Range Limit Delay
Analog Resistive Input Description
84
Section 2 Operation
Write
Decision-Maker
Access
Units
User Interface
Always
s
Low Shutdown Delay: ##s
Always
s
High Shutdown Delay: ##s
Always
Low Warning Limit:
Always
Always
Low Shutdown Limit:
Always
High Warning Limit:
Always
Always
High Shutdown Limit:
Always
Always
Always
Always
Always
s
Always
s
Always
s
Always
Description:
3500
r
Notes
The time that the input
must be within its
shutdown operating
range before a shutdown
protective is indicated
The time that the input
must be within its
shutdown operating
range before a shutdown
protective is indicated
The limit that the input
must drop below to enter
its low warning operating
range
The limit that the input
must drop below to enter
its low warning operating
range
The limit that the input
must drop below to enter
its low shutdown
operating range
The limit that the input
must exceed to enter its
high warning operating
range
The limit that the input
must exceed to enter its
high warning operating
range
The limit that the input
must exceed to enter its
high shutdown operating
range
A percentage of the
parameter value, which
defines the hysteresis for
the protective ranges
Indicates the limit in raw
form when the input will
be considered shorted
high
Indicates the limit in raw
form when the input will
be considered shorted
low
Specifies how much the
raw value needs to
change by before no
longer considered
shorted
Specifies what the inhibit
time should be when the
input is considered
shorted high
Specifies what the inhibit
time should be when the
input is considered
shorted low
Specifies what the
debounce time is on the
input after the inhibit time
is met
A user-defined
description of this IO