Kohler EKOZD Series Service page 188

Marine generator sets
Table of Contents

Advertisement

GENERATOR SET
CONTROLLER WITH
INTEGRATED VOLTAGE
REGULATOR
V7 V8 V9
P6
CONNECTOR
5B
3B
D1
LED OPTIC
BOARD
Figure 11-1 AC Voltage Control Components
Alternator
Controller with
Output
Voltage
Condition
Regulator [
No Output
Overvoltage
Fluctuating
Voltage
* Overvoltage will occur if an outside light source is present when the LED board is removed.
[ See the operation or service manual for operation, setup, and/or troubleshooting.
Figure 11-2 Alternator Assembly Troubleshooting Guide
188 Section 11 Alternator Component Testing and Adjustment
7N
V0
12
11
10
9
8
7
6
5
4
3
2
1
AC1
FP
AC2
FN
AC3
FRX ACTIVATOR
BOARD
Components and Circuits to Test Under Certain Alternator Output Conditions
LED Optic Board
D
D
D
D
D
70
12 LEAD STATOR
ASSEMBLY
MAGNETS
MAGNETS
EXCITER ARMATURE
FRX Activator
Exciter
Board
Armature
D
D
D *
D
D
CONTROL RELAY
CONTACTS
P
P
SOLENOID
S
STARTER
-
BATTERY
ROTOR ASSEMBLY
FIELD WINDING
Rotor Assembly
Stator Assembly
Field Winding
Windings
D
D
D
D
TP-6953
+
TP-6783-3
7/19

Hide quick links: