Kohler EKOZD Series Service page 156

Marine generator sets
Table of Contents

Advertisement

9.4.1
24- to 12-Volt Converter
(32/40EKOZD and 28/35EFKOZD
24-Volt Models Only)
If replacing the converter, carefully disconnect the two
connectors as follows.
1. Converter (24-Volt Models)
Figure 9-1 Converter Location (24-Volt Models)
Small Connector (with Black Tab)
1. Pull the black tab down on the connector until it
clicks. See Figure 9-2.
2. Gently slide the connector off of the converter. See
Figure 9-3.
1
1. Black tab
Figure 9-2 Release the Small Connector (with Black
Tab)
Figure 9-3 Remove the Small Connector
156 Section 9 Component Testing and Adjustment
Large Connector (with Red Tab)
1. Pull the locking red tab down.
2. Press the red and black tab downward and inward
to raise the area of the connector shown in
Figure 9-4.
3. Gently slide the connector off of the converter. See
1
Figure 9-5.
GM95722-J
1
1. Red tab
2. Black tab
3. Red tab with the end raised
Figure 9-4 Locked/Unlocked Position
Figure 9-5 Remove the Large Connector
Locked
Position
2
3
Unlocked
Position
TP-6953
7/19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents