Kohler EKOZD Series Service page 53

Marine generator sets
Table of Contents

Advertisement

From Controller Power-Up
Changes after 3 seconds
Figure 2-12 Decision-Maker 3500 Controller Information Menu Structure
DIAL PUSH
12:00 AM
GENERATOR METER
12/12/12
L1-L2 VOLTS:
###V
L2-L3 VOLTS:
###V
L3-L1 VOLTS:
###V
AVG GEN VOLTAGE L-L:
###V
GEN FREQUENCY:
##.#Hz
L1-L0 VOLTS:
###V
L2-L0 VOLTS:
###V
L3-L0 VOLTS:
###V
AVG GEN VOLTAGE L-N:
###V
GEN FREQUENCY:
##.#Hz
L1 CURRENT:
###A
L2 CURRENT:
###A
L3 CURRENT:
###A
AVG CURRENT:
###A
GEN FREQUENCY:
##.#Hz
L1 POWER:
####W
L2 POWER:
####W
L3 POWER:
####W
TOTAL POWER:
####.#kW
GEN % OF RATED kW:
###%
L1 REACTIVE POWER:
####VAR
L2 REACTIVE POWER:
####VAR
L3 REACTIVE POWER:
####VAR
TOTAL REACTIVE POWER: ####VAR
L1 APPARENT POWER:
####VA
L2 APPARENT POWER:
####VA
L3 APPARENT POWER:
####VA
TOTAL APPARENT POWER: ####VA
GEN % OF RATED kVA:
###%
L1 PF:
L2 PF:
L3 PF:
TOTAL PF:
GEN PHASE ROTATION:
Figure 2-13 Metering Menu
TP-6953
7/19
Alternates
8 seconds
F
METERING
GENERATOR METERING
ENGINE METERING
BATTERY CHARGER METERING - - >
OVERVIEW
PARALLELING METERING
DIAL PUSH
12:00 AM
ENGINE METERING
12/12/12
ENGINE SPEED:
####RPM
ECM BATTERY VOLTAGE: ##.#VDC
GEN BATTERY VOLTAGE: ##.#VDC
GENSET CONTROLLER TEMP:###_F
OIL PRESSURE:
OIL TEMPERATURE:
COOLANT TEMPERATURE:
COOLANT PRESSURE:
FUEL LEVEL:
FUEL PRESSURE:
FUEL TEMPERATURE:
FUEL RATE:
###GAL/h
FUEL USED LAST RUN:
CRANKCASE PRESSURE:
INTAKE AIR PRESSURE:
INTAKE AIR TEMPERATURE: ###_F
BATTERY X METER
STATUS:
OUTPUT VOLTAGE:
OUTPUT CURRENT:
CHARGER STATE:
CHARGER TEMP:
REDUCED OUTPUT ACTIVE: YES/NO
TEMP COMPENSATION ACTIVE: YES/NO
SOFTWARE VERSION: ###########
#.##
#.##
#.##
#.##
###
From Controller Sleep/Idle Operation
every
DIAL CLICK
METERING
GENERATOR INFO
CONTROLLER CONFIG
I/O
ACTIVE EVENTS
DIAL TURN
DIAL PUSH at METERING. Go to Figure 2-13.
DIAL PUSH at GENERATOR INFO. Go to Figure 2-14.
DIAL PUSH at CONTROLLER CONFIG. Go to Figure 2-15.
DIAL PUSH at I/O. Go to Figure 2-16.
12:00 AM
12/12/12
Note: Battery Charger Metering menu options appear but do not apply
to these models.
DIAL TURN
DIAL PUSH
DIAL PUSH
###PSI
###_F
###_F
F
###PSI
Alternates every
###%
8 seconds
###PSI
###_F
###GAL
###PSI
###PSI
Alternates every
12:00 AM
12/12/12
8 seconds
##.#VDC
##.#A
###_F
Alternates
every
8 seconds
DIAL PUSH
PARALLEL METERING
CONNECTED TO BUS: TRUE/FALSE
AVG BUS VOLTAGE L-L:
AVG GEN VOLTAGE L-L:
BUS FREQUENCY:
GEN FREQUENCY:
BUS TOTAL POWER:
BUS % OF RATED kW:
BUS % OF RATED kVAR:
Section 2 Operation
12:00 AM
12/12/12
###.#V
###.#V
##.##Hz
##.##Hz
#####.#kW
###%
###%
53