Kohler EKOZD Series Service page 65

Marine generator sets
Table of Contents

Advertisement

SiteTecht Parameter
Voltage Selector Switch
Voltage Selector Switch Position
Voltage Selector Switch Max Positions
Voltage Selector Switch Position 1 Voltage
Voltage Selector Switch Position 1 Frequency
Voltage Selector Switch Position 1 Voltage Phase
Connection
Voltage Selector Switch Position 2 Voltage
Voltage Selector Switch Position 2 Frequency
Voltage Selector Switch Position 2 Voltage Phase
Connection
Voltage Selector Switch Position 3 Voltage
Voltage Selector Switch Position 3 Frequency
Voltage Selector Switch Position 3 Voltage Phase
Connection
Genset System Configuration
Genset System Voltage
Genset System Frequency
Genset Voltage Phase Connection
Genset Power Rating
Genset Apparent Power Rating
Genset Rated Current
Genset System Battery Voltage
Prime Power Application
Current Transformer Ratio
Local Start Mode
Measurement System
Alarm Silence Always Allowed
NFPA 110 Enabled
Cool Down Temperature Override
Oil Sensor Type
Public CAN Protocol
Display Contrast
Using Voltage Selector Switch
Genset System Language
Genset Maximum Percent Capacity
Generator Overloaded Percent
Under Frequency Shed Level
Base Load Add Time
Base Over Load Shed Time
Base Under Frequency Shed Time
TP-6953
7/19
Write
Decision-Maker
Access
Units
User Interface
Not supported for these models.
Stopped
V
System Voltage L- L: ###V
Stopped
Hz
System Frequency: ##.#Hz
Stopped
System Phase: Single/Single
Dog/Three-Wye/ Three-Delta
Locked
kW
kW Rating: ####kW
Stopped
kVA
None
A
Rated Current: ###A
Stopped
V
Battery Voltage: ##V
Locked
Operating Mode: Standby/Prime
Locked
Not supported for these models.
Always
Units: Metric/English
Always
Alarm Silence: Always/Auto Only
Always
NFPA Defaults: On/Off
Always
Cooldown Override: On/Off
Stopped
Not supported for these models.
Always
Contrast: ###
Stopped
Always
Language: English
Always
%
Always
%
Always
%
Always
s
Always
s
Always
s
3500
r
Notes
The generator operating
voltage
The generator operating
frequency
The generator number of
phases (single or three)
The generator operating
power rating in kW
The generator operating
apparent power rating in
kVA
Calculated from power
rating, voltage, and
connection
The generator operating
battery voltage
Indicates whether the
generator set is in a
prime power application
Indicates whether to use
the English or Metric
measurements system
for display of parameter
values and their units
When true, the alarm can
be silenced when the
controller is in any state;
when false, the alarm can
only be silenced in the
Auto state
Indicates whether
NFPA110 defaults are
enabled
Indicates whether the
engine's cooled-down
parameter should be
overridden during the
time delay
Indicates the type of oil
sensor
Section 2 Operation
65