possibility of carbon monoxide poisoning.
attention if the condition of affected persons does not improve
within minutes of breathing fresh air.
Inspecting the exhaust system. Carbon monoxide can
cause severe nausea, fainting, or death. For the safety of
the craft's occupants, install a carbon monoxide detector.
Never operate the generator set without a functioning carbon
monoxide detector.
Inspect the detector before each
generator set use.
Operating the generator set. Carbon monoxide can cause
severe nausea, fainting, or death. Be especially careful if
operating the generator set when moored or anchored under
calm conditions because gases may accumulate. If operating
the generator set dockside, moor the craft so that the exhaust
discharges on the lee side (the side sheltered from the wind).
Always be aware of others, making sure your exhaust is
directed away from other boats and buildings.
NOTICE
Electrostatic discharge damage. Electrostatic discharge
(ESD) damages electronic circuit boards.
electrostatic discharge damage by wearing an approved
grounding wrist strap when handling electronic circuit boards
or integrated circuits. An approved grounding wrist strap
provides a high resistance (about 1 megohm), not a direct
short, to ground.
9.1 Controller Handling
The controller contains an electronic printed circuit
board (PCB) that is sensitive to a variety of elements and
can
be
damaged
during
transportation, or storage. Observe the following when
working with the controller.
9.1.1
Handling
Don't bend or drop the controller or any of its
D
components.
Don't strike the controller or any of its components
D
with a hard object.
Clean a dusty or dirty controller only with a vacuum
D
cleaner, dry brush, and/or aerosol spray cans
specifically
for
electronic
components. Aerosol spray cans are typically found
with computer supplies.
Never attempt component-level circuit repairs as this
D
may void third party certification.
Never remove or install a controller with the power
D
connected.
154 Section 9 Component Testing and Adjustment
Seek medical
Prevent
removal,
installation,
equipment
and
Label wiring when disconnecting it for reconnection
D
later.
Remove wiring harnesses with plug connectors by
D
pressing the locking tab(s) and pulling on the plug
straight out to remove the wiring harness plug from
the controller socket.
Use caution when removing a controller in a
D
paralleling system.
running, the controller's harness pins may be
energized.
If the start signal to a paralleling system is only
D
provided to one controller, consider using the
emergency stop instead of cycling power on the
controller otherwise the entire system may stop.
Pressing the AUTO-RUN on another generator set
before cycling power avoids this situation.
9.2 Other Service Parts
The removal and installation of service parts is covered
by the following generic procedure.
include plug-in relays, switches, lamps, meters, gauges,
brackets, and other hardware.
WARNING
Accidental starting.
Can cause severe injury or death.
Disconnect the battery cables before
working
on
Remove the negative (- ) lead first
when disconnecting the battery.
Reconnect the negative (- ) lead last
when reconnecting the battery.
Disabling the generator set.
cause severe injury or death.
generator set or equipment connected to the set, disable the
generator set as follows: (1) Press the generator set off/reset
button to shut down the generator set. (2) Disconnect the
power to the battery charger, if equipped. (3) Remove the
battery cables, negative (- ) lead first. Reconnect the negative
(- ) lead last when reconnecting the battery. Follow these
precautions to prevent the starting of the generator set by the
remote start/stop switch.
If another generator set is
Service parts
the
generator
set.
Accidental starting can
Before working on the
TP-6953