Kohler EKOZD Series Service page 71

Marine generator sets
Table of Contents

Advertisement

SiteTecht Parameter
Circuit Breaker Current Fault Delay
Volts Hertz Okay Time Delay
Sync Mode In Auto
Sync Mode In Run
Circuit Breaker Phase Angle Fault Limit
Circuit Breaker Phase Angle Fault Delay
Dead Bus Level
Pickup Acceptable Voltage Window
Dropout Acceptable Voltage Window
Pickup Acceptable Frequency Window
Dropout Acceptable Frequency Window
Stand Alone Operation
PGen Baud Rate
PGen Node Id
PGen Nodes Connected
PGen Nodes Disconnected
Fail To Open Delay
Fail To Close Delay
Voltage Match Proportional Gain
Voltage Match Integral Gain
Voltage Match Derivative Gain
Frequency Match Proportional Gain
Frequency Match Integral Gain
Frequency Match Derivative Gain
Phase Match Proportional Gain
Phase Match Integral Gain
Phase Match Derivative Gain
Generator Paralleling Breaker
External Bias Inputs Enabled
Synchronization Metering
Sync Time Remaining
Sync Dwell Time Remaining
Sync Status Generator V Hz OK
Sync Status Voltage Matched
Sync Status Frequency Matched
Sync Status Phase Matched
Sync Check Matched Ok
Real Power Load Sharing
Real Power Baseload Setpoint
Real Power Disconnect Level
Real Power Ramp Rate
Real Power Droop Slope
Speed Bias
Load Enable
Base Load Mode
System Load Control
System Sync Control
Trims Enabled
Real Power Sharing Proportional Gain
Real Power Sharing Integral Gain
Real Power Sharing Derivative Gain
Torque Sharing Proportional Gain
TP-6953
7/19
Write
Decision-Maker
Access
Units
User Interface
Always
s
CB Current Fault Delay: ##.#s
Always
s
Volts-Hz OK Delay: ##.#s
Always
Sync Mode in Auto:
Invalid/Off/Passive/Check/
Active/Dead Field
Always
Sync Mode in Run:
Invalid/Off/Passive/Check/
Active/Dead Field
Always
CB Phase Fault Limit: ##.#
_
Always
s
CB Phase Fault Delay: ##.#s
Always
%
Dead Bus Level: ##.#%
Always
%
Voltage OK Pickup: ##.#%
Always
%
Voltage OK Dropout: ##.#%
Always
Hz
Frequency OK Pickup: ##.#Hz
Always
Hz
Frequency OK Dropout: ##.#Hz
Always
Stand Alone Mode: On/Off
Always
b/s
PGEN Baud Rate: OFF/9600
b/s/19200 b/s/38400 b/s/
57600 b/s/115200 b/s
None
PGEN Node ID: ##
None
PGEN Nodes Online: ##
None
PGEN Nodes Offline: ##
Always
s
Fail to Open Delay: ##s
Always
s
Fail to Close Delay: ##s
Always
Voltage Match P Gain: ##.##
Always
Voltage Match I Gain: ##.##
Always
Voltage Match D Gain: ##.##
Always
Freq Match P Gain: ##.##
Always
Freq Match I Gain: ##.##
Always
Freq Match D Gain: ##.##
Always
Phase Match P Gain: ##.##
Always
Phase Match I Gain: ##.##
Always
Phase Match D Gain: ##.##
None
Always
None
s
Sync Time Remaining: ####s
None
s
Dwell Time Remaining: ##.#s
None
Volts-Hz OK: True/False
None
Voltage Matched: True/False
None
Frequency Matched: True/False
None
Phase Matched: True/False
None
In Sync: True/False
Always
%
Always
%
kW Disconnect Level: ##.#%
Always
%/s
kW Ramp Rate: ##.#%/s
Always
%@FL
None
Speed Bias: ###.##
Always
Load Enabled: On/Off
Always
Always
System Load Control: On/Off
Always
System Sync Control: On/Off
Always
Trims Enabled: On/Off
Always
kW Sharing P Gain: ##.##
Always
kW Sharing I Gain: ##.##
Always
kW Sharing D Gain: ##.##
Always
3500
r
Notes
10 = 1.0 Sec
_
(Sec x 10)
(Sec x 10)
Bit 0: Gen_VHz_OK
Bit 1: Synch_V_Matched
Bit 2:
Synch_Freq_Matched
Bit 3:
Synch_Phase_Matched
250 = 25.0%
100 = 10.0% of rated kW
50 = 5.0% of rated
kW/Sec
20 = 2.0 % of rated
speed @ 100% rated kW
5000 = 50.00 Note:
speed bias is equal to
% speed x 10 (5000 - >
50.00 - > +5% Voltage)
Section 2 Operation
71