Table of Contents

Advertisement

15.9
Capron - 3141417 - 03/20 - EHG-0021-02EN
Fault
Any change in the taste or
odour of the water
Deposits in the water tank
and/or water-carrying
components

Body

Fault
Flap hinges/door hinges
are difficult to operate
Hinges/joints in the bath-
room unit/toilet compart-
ment are difficult to oper-
ate/make a grating noise
Storage compartment
hinges are difficult to oper-
ate/make a grating noise
The authorised dealers and service centres are available for any spare
parts requirement.
Troubleshooting
Cause
Tank filled with dirty water
Fuel filled into the water
tank by mistake
Microbiological deposits in
the water system
Water excessively long in
the water tank and in wa-
ter-carrying components
Cause
Flap/door hinges are not
(sufficiently) lubricated
Hinges/joints are not (suf-
ficiently) lubricated
Storage compartment
hinges are not (suffi-
ciently) lubricated
15
Remedy
Clean water system me-
chanically and chemically;
then disinfect and rinse
copiously with drinking
water
Clean water system me-
chanically and chemically;
then disinfect and rinse
copiously with drinking
water. If not successful:
Contact a specialist work-
shop
Clean water system me-
chanically and chemically;
then disinfect and rinse
copiously with drinking
water
Clean water system me-
chanically and chemically;
then disinfect and rinse
copiously with drinking
water
Remedy
Lubricate flap hinges/door
hinges with acid-free and
resin-free grease
Lubricate hinges/joints
with solvent-free and acid-
free grease
Spray cans of-
ten contain sol-
vents
Lubricate storage com-
partment hinges with acid-
free and resin-free grease