Safety/Drainage Valve - Capron T58 Manual

Table of Contents

Advertisement

Fault display
10.2.6
Position
Filling/emptying domestic
water container
Filling the domestic water
container with water:
Capron - 3141417 - 03/20 - EHG-0021-02EN
The service menu contains items that generally only need to be set once
(language, background brightness, calibration), as well as information for
service centres (version numbers).
The warning symbol (Fig. 111,7) flashes in the event of a warning. The
heater continues to operate. In the event of only a temporary fault, the warn-
ing symbol goes out automatically.
In the event of a warning, the control unit displays the error code for the
fault. The heater is switched off. Press rotary push button to restart the
heater.
Further information can be obtained in the manufacturer's instruction
manual.

Safety/drainage valve

The heater is equipped with a safety/drainage valve (Fig. 112). The safety/
drainage valve prevents water for the production of hot water from freezing,
when there is frost and the heater is not switched on.
When the vehicle is not used for a long period of time, open the
safety/drainage valve and empty the heater.
At temperatures below 2 °C the safety/drainage valve opens automati-
cally. Only if the temperature of the safety/drainage valve lies above
6 °C can it be shut again.
The water pump and the water fittings are not protected against freezing
by the safety/drainage valve.
The drainage neck of the safety/drainage valve has to be free of dirt
(e.g. leaves, ice) at all times.
Fig. 112
Safety/drainage valve
See section 11.2.7.
The domestic water container can be supplied with water from the water
tank.
Switch on the 12 V power supply on the panel.
Close the safety/drainage valve. Turn the knob (Fig. 112,1) perpendicu-
lar to the safety/drainage valve and push the push button (Fig. 112,2) in.
10