15

Troubleshooting

15.1
15.2
Capron - 3141417 - 03/20 - EHG-0021-02EN
Chapter overview
This chapter contains instructions about possible faults in your vehicle.
The faults are listed with their possible causes and corresponding remedies.
The specified faults can be remedied with relative ease and without a great
deal of specialised knowledge. In the event that the remedies detailed in this
instruction manual should not be successful, an authorised specialist work-
shop must find and eliminate the cause of the fault.

Braking system

 Have defects on the braking system immediately remedied by an au-
thorised specialist workshop.

Electrical system

When the living area battery is changed, only use batteries of the same
type and the same capacity.
See chapter 9 for changing the fuses.
Fault
Road light system does
no longer work correctly
Interior lighting does not
work
The electrically operated
entrance step cannot be
moved in or out
The entrance step does
not extend or only
partially (in the winter)
No 230 V power supply in
spite of connection
Troubleshooting
Cause
Bulb is defective
Fuse is defective
Illuminant, plug con-
nector or cable faulty
Fuse on the trans-
former/rectifier is defec-
tive
The mechanics are iced
up
The protection device
(pinch protection) has
triggered due to a over-
load current
230 V automatic circuit
breaker has triggered
15
Remedy
Replace bulb. Note volts and
watts specifications
Replace fuse
Contact customer service
Replace fuse on the trans-
former/rectifier
Clean the entrance step, re-
move ice
Switch on 230 V automatic
circuit breaker
161