Table of Contents

Advertisement

15
Troubleshooting
15.3
164
Fault
Battery charge through
solar module not working
Living area battery over-
loaded ("hot")

Gas system

 In case of a defect of the gas system (gas odour, high gas consump-
tion) there is danger of explosion! Close regulator tap on the gas bot-
tle immediately. Open doors and windows and ventilate well.
 If the gas system is defective: Do not smoke; do not ignite any open
flames, and do not operate electric switches (light switches etc.).
Check the tightness of gas-conducting parts and lines with leakage
search spray. Do not check with an open flame.
 Have the defective gas system repaired by an authorised specialist
workshop.
Fault
No gas
Cause
Electrical connection to
solar module interrupted
Fuse is defective
Solar charge regulator
defective
Battery selection switch
set wrongly
Defective load sensor or
relay
Cause
Gas bottle is empty
Gas isolator tap closed
Regulator tap on the gas
bottle is closed
External temperature is
too low (-42 °C for pro-
pane gas, 0 °C for butane
gas)
Built-in appliance is defec-
tive
Remedy
Check plug connectors and
cables
Replace fuse on the trans-
former/rectifier
Contact customer service
Move position of battery se-
lection switch
Pull out the jumbo flat fuse
on the living area battery,
then contact customer ser-
vice
Remedy
Change gas bottle
Open the gas isolator tap
Open regulator tap on the
gas bottle
Wait for higher external
temperatures
Contact customer service
Capron - 3141417 - 03/20 - EHG-0021-02EN