Testing Voice Service And Caller Id - Viavi OneExpert DSL User Manual

Hide thumbs Also See for OneExpert DSL:
Table of Contents

Advertisement

2
From the Copper menu, touch Load Coil.
The Load Coil Detector menu appears.
The count appears in the box. If at least one load coil is detected, the
distance to the first load appears.
NOTE:
The distance to first load measurement assumes no other impair-
ments are present between the OneExpert DSL and the first load
coil. If other impairments are present, accuracy is reduced.
If voltage greater than 50V peak is present, the test will abort.
If noise, a short, or an open is detected, it appears on this screen.
3
Optional. Select Refresh to restart the test.
4
To save the results to a report, use the Tray menu
on page
5
To learn what your results mean, see
Results".
Detecting load coils is complete.

Testing voice service and Caller ID

The POTS dialer allows you to place and receive voice calls to verify that
the service is working properly. You can also use the dialer for the following
tasks:
to drop battery for opens testing
to establish a quiet termination for balance and noise tests
to determine if loss at 1004 Hz is acceptable
to test incoming caller ID number and name
The following procedure describes how to test voice service and caller ID.
November 2015
49).
OneExpert DSL User's Guide
22052280, Rev 006
Chapter 12 Copper Testing

Testing voice service and Caller ID

("Saving a report"
"Load coil"
in
Chapter 14 "Test
Page 161