Emc (Electromagnet Compatibility); Emission; Immunity - Star Micronics TUP500 Series Product Specifications Manual

Hide thumbs Also See for TUP500 Series:
Table of Contents

Advertisement

5.2. EMC (Electromagnet Compatibility)

Emission

5.2.1.
Conforms to EN61000-6-3 The following shows the details.
Use the optional power adapter for the power supply.
(1) Field Emission Test/Power Line Continuity Test
Standards Cited
EN55022
(2) Power High Frequency Current Test
Standards Cited
EN61000-3-2
Note: This product is rated at power of 75 W or less, so it is not targeted for the power harmonics cur-
rent test regulations.
(3) Flicker Test
Standards Cited
EN61000-3-3

Immunity

5.2.2.
Conforms to EN55024. The following shows the details.
Use the optional power adapter for the power supply.
(1) Static Electricity Discharge Test
Standards Cited
EN61000-4-2
(2) Electromagnetic Field Radiated Immunity Test
Standards Cited
EN61000-4-3
(3) Electrical Fast Transient Burst Test
Standards Cited
EN61000-4-4
(4) Lightening Surge Test
Standards Cited
EN61000-4-5
TUP500 Series Product Specifications
Limit Value
Class B
Category
Class A
Pst Short Peak Flicker Value 1.0
Dc(%): Relative Constant State Voltage Change 3.3%
Dmax(%): Max. Relative Voltage Change 4.0%
D(t) (ms): Relative Voltage Change Characteristics 500 ms
Testing Levels
Touch
Level 2
(Voltage: 4KV)
Level 2
(Electromagnetic Field Strength: 3 V/m)
Power Supply Port
Level 2
(Voltage Peak: 1.0 KV)
Repeat Ratio: 5 KHz)
Testing Levels
Line-to-Line
Level 2
Level 3
(Voltage: 1.0KV)
(Voltage: 2.0KV)
Limit Value
In-air
Level 3
(Voltage: 8KV)
Testing Levels
Testing Levels
Control Port
Level 2
(Voltage Peak: 0.5KV)
Repeat Ratio: 5 KHz)
Line-to-Earth
5-2