Mitsubishi Electric MELSEC iQ-R Series User Manual page 111

Channel isolated thermocouple input module/channel isolated rtd input module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Address
Decimal (hexadecimal)
CH1
CH2
CH3
CH4
46 (2EH)
47 (2FH)
48 (30H)
49 (31H)
50
51
52
53
(32H)
(33H)
(34H)
(35H)
58 (3AH)
59 to 61 (3BH to 3DH)
62
64
66
68
(3EH)
(40H)
(42H)
(44H)
63
65
67
69
(3FH)
(41H)
(43H)
(45H)
78
80
82
84
(4EH)
(50H)
(52H)
(54H)
79
81
83
85
(4FH)
(51H)
(53H)
(55H)
94
98
102
106
(5EH)
(62H)
(66H)
(6AH)
95
99
103
107
(5FH)
(63H)
(67H)
(6BH)
96
100
104
108
(60H)
(64H)
(68H)
(6CH)
97
101
105
109
(61H)
(65H)
(69H)
(6DH)
126
127
128
129
(7EH)
(7FH)
(80H)
(81H)
134
136
138
140
(86H)
(88H)
(8AH)
(8CH)
135
137
139
141
(87H)
(89H)
(8BH)
(8DH)
150 to 156 (96H to 9CH)
157 (9DH)
158, 159 (9EH, 9FH)
160, 161 (A0H, A1H)
162 (A2H)
163 (A3H)
164, 165 (A4H, A5H)
166
167
168
169
(A6H)
(A7H)
(A8H)
(A9H)
174 to 189 (AEH to BDH)
190
202
214
226
(BEH)
(CAH)
(D6H)
(E2H)
191
203
215
227
(BFH)
(CBH)
(D7H)
(E3H)
192
204
216
228
(C0H)
(CCH)
(D8H)
(E4H)
193
205
217
229
(C1H)
(CDH)
(D9H)
(E5H)
CH5
CH6
CH7
CH8
54
55
56
57
(36H)
(37H)
(38H)
(39H)
70
72
74
76
(46H)
(48H)
(4AH)
(4CH)
71
73
75
77
(47H)
(49H)
(4BH)
(4DH)
86
88
90
92
(56H)
(58H)
(5AH)
(5CH)
87
89
91
93
(57H)
(59H)
(5BH)
(5DH)
110
114
118
122
(6EH)
(72H)
(76H)
(7AH)
111
115
119
123
(6FH)
(73H)
(77H)
(7BH)
112
116
120
124
(70H)
(74H)
(78H)
(7CH)
113
117
121
125
(71H)
(75H)
(79H)
(7DH)
130
131
132
133
(82H)
(83H)
(84H)
(85H)
142
144
146
148
(8EH)
(90H)
(92H)
(94H)
143
145
147
149
(8FH)
(91H)
(93H)
(95H)
170
171
172
173
(AAH)
(ABH)
(ACH)
(ADH)
238
250
262
274
(EEH)
(FAH)
(106H)
(112H)
239
251
263
275
(EFH)
(FBH)
(107H)
(113H)
240
252
264
276
(F0H)
(FCH)
(108H)
(114H)
241
253
265
277
(F1H)
(FDH)
(109H)
(115H)
Name
Default
value
Alert output setting (Process
FFFFH
alarm)
Alert output setting (Rate alarm)
Alert output flag (Process alarm)
0
Alert output flag (Rate alarm)
0
Disconnection detection flag
0
CH Scaling value
0
Scaling enable/disable setting
00FFH
System area
CH Scaling range lower limit
0
value
CH Scaling range upper limit
0
value
CH Scaling width lower limit
0
value
CH Scaling width upper limit
0
value
CH Process alarm lower lower
-2000
limit value
CH Process alarm lower upper
-2000
limit value
CH Process alarm upper lower
12000
limit value
8500
CH Process alarm upper upper
12000
limit value
8500
CH Rate alarm alert detection
0
cycle setting
CH Rate alarm upper limit
0
value
CH Rate alarm lower limit
0
value
System area
Disconnection detection
1
automatic clear enable/disable
setting
Mode switching setting
0
System area
Disconnection detection enable/
0
disable setting
System area
Conversion setting at
1111H
disconnection detection
CH Conversion setting value at
0
disconnection detection
System area
CH Factory default setting
0
offset value (L)
CH Factory default setting
0
offset value (H)
CH Factory default setting gain
0
value (L)
CH Factory default setting gain
0
value (H)
Appendix 3 Buffer Memory Areas
Data
Auto
type
refresh
Setting
Monitor
Monitor
Monitor
Monitor
Setting
Setting
Setting
Setting
Setting
Setting
Setting
*2
Setting
*2
*2
Setting
*2
Setting
A
Setting
Setting
Setting
Setting
Setting
Setting
Setting
User
range
setting
User
range
setting
User
range
setting
User
range
setting
APPX
109

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60td8-gR60rd8-g

Table of Contents