Mitsubishi Electric MELSEC iQ-R Series User Manual page 103

Channel isolated thermocouple input module/channel isolated rtd input module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Un\G400 to Un\G3599
Address
Decimal (hexadecimal)
CH1
CH2
CH3
CH4
400
600
800
1000
(190H)
(258H)
(320H)
(3E8H)
401
601
801
1001
(191H)
(259H)
(321H)
(3E9H)
402
602
802
1002
(192H)
(25AH)
(322H)
(3EAH)
403 to
603 to
803 to
1003 to
408
608
808
1008
(193H
(25BH
(323H
(3EBH
to
to
to
to
198H)
260H)
328H)
3F0H)
409
609
809
1009
(199H)
(261H)
(329H)
(3F1H)
410 to
610 to
810 to
1010 to
429
629
829
1029
(19AH
(262H
(32AH
(3F2H
to
to
to
to
1ADH)
275H)
33DH)
405H)
430
630
830
1030
(1AEH)
(276H)
(33EH)
(406H)
431
631
831
1031
(1AFH)
(277H)
(33FH)
(407H)
432,
632,
832,
1032,
433
633
833
1033
(1B0H,
(278H,
(340H,
(408H,
1B1H)
279H)
341H)
409H)
434
634
834
1034
(1B2H)
(27AH)
(342H)
(40AH)
435
635
835
1035
(1B3H)
(27BH)
(343H)
(40BH)
436
636
836
1036
(1B4H)
(27CH)
(344H)
(40CH)
437
637
837
1037
(1B5H)
(27DH)
(345H)
(40DH)
438
638
838
1038
(1B6H)
(27EH)
(346H)
(40EH)
439
639
839
1039
(1B7H)
(27FH)
(347H)
(40FH)
440
640
840
1040
(1B8H)
(280H)
(348H)
(410H)
441
641
841
1041
(1B9H)
(281H)
(349H)
(411H)
442
642
842
1042
(1BAH)
(282H)
(34AH)
(412H)
443
643
843
1043
(1BBH)
(283H)
(34BH)
(413H)
444
644
844
1044
(1BCH)
(284H)
(34CH)
(414H)
445
645
845
1045
(1BDH)
(285H)
(34DH)
(415H)
446
646
846
1046
(1BEH)
(286H)
(34EH)
(416H)
447
647
847
1047
(1BFH)
(287H)
(34FH)
(417H)
CH5
CH6
CH7
CH8
1200
1400
1600
1800
(4B0H)
(578H)
(640H)
(708H)
1201
1401
1601
1801
(4B1H)
(579H)
(641H)
(709H)
1202
1402
1602
1802
(4B2H)
(57AH)
(642H)
(70AH)
1203 to
1403 to
1603 to
1803 to
1208
1408
1608
1808
(4B3H
(57BH
(643H
(70BH
to
to
to
to
4B8H)
580H)
648H)
710H)
1209
1409
1609
1809
(4B9H)
(581H)
(649H)
(711H)
1210 to
1410 to
1610 to
1810 to
1229
1429
1629
1829
(4BAH
(582H
(64AH
(712H
to
to
to
to
4CDH)
595H)
65DH)
725H)
1230
1430
1630
1830
(4CEH)
(596H)
(65EH)
(726H)
1231
1431
1631
1831
(4CFH)
(597H)
(65FH)
(727H)
1232,
1432,
1632,
1832,
1233
1433
1633
1833
(4D0H,
(598H,
(660H,
(728H,
4D1H)
599H)
661H)
729H)
1234
1434
1634
1834
(4D2H)
(59AH)
(662H)
(72AH)
1235
1435
1635
1835
(4D3H)
(59BH)
(663H)
(72BH)
1236
1436
1636
1836
(4D4H)
(59CH)
(664H)
(72CH)
1237
1437
1637
1837
(4D5H)
(59DH)
(665H)
(72DH)
1238
1438
1638
1838
(4D6H)
(59EH)
(666H)
(72EH)
1239
1439
1639
1839
(4D7H)
(59FH)
(667H)
(72FH)
1240
1440
1640
1840
(4D8H)
(5A0H)
(668H)
(730H)
1241
1441
1641
1841
(4D9H)
(5A1H)
(669H)
(731H)
1242
1442
1642
1842
(4DAH)
(5A2H)
(66AH)
(732H)
1243
1443
1643
1843
(4DBH)
(5A3H)
(66BH)
(733H)
1244
1444
1644
1844
(4DCH)
(5A4H)
(66CH)
(734H)
1245
1445
1645
1845
(4DDH)
(5A5H)
(66DH)
(735H)
1246
1446
1646
1846
(4DEH)
(5A6H)
(66EH)
(736H)
1247
1447
1647
1847
(4DFH)
(5A7H)
(66FH)
(737H)
Name
CH Measured temperature value
System area
CH Scaling value
System area
CH Logging hold flag
System area
CH Range setting monitor
(Thermocouple type)
(for the thermocouple input module)
CH Range setting monitor
(Resistance temperature detector
type)
(for the RTD input module)
CH Range setting monitor (offset/
gain setting)
System area
CH Head pointer
CH Latest pointer
CH Number of logging data
CH Trigger pointer
CH Current logging read pointer
CH Previous logging read pointer
CH Logging read points monitor
value
CH Logging cycle monitor value
(s)
CH Logging cycle monitor value
(ms)
System area
CH Trigger generation time (First/
Last two digits of the year)
CH Trigger generation time
(Month/Day)
CH Trigger generation time (Hour/
Minute)
CH Trigger generation time
(Second/Day of the week)
Appendix 3 Buffer Memory Areas
Default
Data
Auto
value
type
refresh
0
Monitor
0
Monitor
0
Monitor
0000H
Monitor
0000H
Monitor
0000H
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
-1
Monitor
-1
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
APPX
101
A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60td8-gR60rd8-g

Table of Contents