5.4 Active Line Modules
5.4.3.4

X9 terminal strip

Table 5- 32
Max. connectable cross-section:
- terminal 1 ... 6: 2.5 mm
- terminals L1, L2: 35 mm
Note
Connecting fan supply, with frame sizes FX and GX
The fan supply for frame sizes FX and GX is connected directly to fuse holders -F10 and -F11.
5.4.3.5

X41 EP terminal / temperature sensor connection

Table 5- 33
Connector
Max. connectable cross-section: 1.5 mm
Electric shock in the event of voltage flashovers at the temperature sensor
Voltage flashovers in the signal electronics can occur in motors without safe electrical
separation of the temperature sensors.
• Only use temperature sensors that fully comply with the specifications of the safety
• If safe electrical separation cannot be guaranteed (for linear motors or third-party
198
Terminal strip X9
Terminal
1
2
3
4
5
6
L1
L2
2
2
Terminal strip X41
Terminal
1
2
3
4
WARNING
isolation.
motors, for example), use a Sensor Module External (SME120 or SME125) or Terminal
Module TM120.
Signal name
P24V
M
Bypass contactor control for Active Interface Module, X609:11
Pre-charge contactor
control
Connection for fan sup-
ply
(frame sizes HX and JX
only)
Function
EP M1 (Enable Pulses)
EP +24 V (Enable Pulses)
- Temp
+ Temp
2
Technical specifications
External 24 V DC supply
Voltage: 24 VDC (20.4 ... 28.8 V)
Current consumption: max. 1.7 A
for Active Interface Module, X609:12
for Active Interface Module, X609:9
for Active Interface Module, X609:10
380 ... 480 VAC / 500 ... 690 VAC
Current consumption: See Technical data
Technical specifications
Supply voltage: 24 VDC (20.4 ... 28.8 V)
Current consumption: 10 mA
Temperature sensor connection KTY84-
1C130 / PT1000 / PTC
Air-cooled chassis power units
Equipment Manual, 06/2020, 6SL3097-5AE00-0BP3