Motor Modules
6.2 Motor Modules Chassis-2
6.2.5

Installation

The Motor Module Chassis-2 is secured using two M10 bolts on the top of the device, which
are screwed onto the rear mounting panel of the control cabinet.
Then the Motor Module Chassis-2 is fastened to the mounting surface of the control cabinet
using a mounting bracket.
When installing the device without using a suitable mounting aid, the device may be
damaged or cause injury.
When installing the Motor Module in a control cabinet without using a suitable mounting
aid, the Motor Module may be damaged or cause injury.
• When installing the Motor Module in a control cabinet, use a suitable mounting aid so
• When installing the device in a Rittal VX25 or TS8 control cabinet, we recommend using
Injury or damage to the device if it topples or rolls away.
During installation, the Motor Module can topple over or roll away. This can result in injuries
or damage to the device.
• Secure the Motor Module so that it cannot topple over or roll away.
310
CAUTION
that the device can be horizontally rolled into the control cabinet.
the mounting aid with Article No. 6SL3766-1CH02-0AA0.