Siemens SINAMICS S120 Manual page 397

Air-cooled chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Table 8- 32
Technical data of the dv/dt filter plus voltage peak limiter, 500 V ... 690 V 3 AC, Part 2
Article number
Suitable for Motor Module
Type rating of the Motor
Module
I
thmax
Degree of protection
dv/dt reactor
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
Connections
- To the Motor Module
- Load
- PE
Max. permissible cable
length between dv/dt reac-
tor and motor
Dimensions
Width
Height
Depth
Weight, approx.
Voltage peak limiter
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
Connections
- To the dv/dt reactor
- DC
- PE
Dimensions
Width
Height
Depth
Weight, approx.
Two dv/dt reactors are required for these dv/dt filters. The technical data provided applies to one dv/dt reactor.
1)
Note
Cable lengths for versions with two dv/dt reactors
For versions with 2 dv/dt reactors, the cable lengths specified in the table do not change.
Air-cooled chassis power units
Equipment Manual, 06/2020, 6SL3097-5AE00-0BP3
6SL3000-
2DH34-1AA0
6SL3320-
1TG34-1AA3
kW
400
A
410
IP00
kW
0.786
kW
0.826
kW
0.884
M12
M12
M6
m
mm
460
mm
385
mm
312
kg
147
kW
0.051
kW
0.048
kW
0.043
M8
M8
M8
mm
309
mm
1312.5
mm
400
kg
48
Motor-side power components
8.3 dv/dt filter plus Voltage Peak Limiter
2DH35-8AA0
2DH38-1AA0
1TG34-7AA3
1TG37-4AA3
1TG35-8AA3
1TG38-1AA3
450 / 560
710 / 800
575
810
IP00
IP00
0.862
0.828
0.902
0.867
0.964
0.927
M12
2 x M12
M12
2 x M12
M6
M6
300 (shielded)
450 (unshielded)
460
445
385
385
312
312
172
160
0.063
0.106
0.059
0.1
0.054
0.091
M8
M10
M8
M10
M8
M8
309
309
1312.5
1312.5
400
400
48
2DH41-3AA0
1)
1TG38-8AA3
1TG41-0AA3
1TG41-3AA3
900 / 1000 / 1200
1270
IP00
0.865
0.904
0.966
2 x M12
2 x M12
M6
445
385
312
164
0.15
0.14
0.128
M10
M10
M8
309
1312.5
400
72
72
1)
395

Advertisement

Table of Contents
loading