Siemens SINAMICS S120 Manual page 285

Air-cooled chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Table 6- 18
Technical data for Motor Modules, 675 ... 1035 V DC (line voltage 3 AC 500 ... 690 V), Part 3
Article number
Output current
- Rated current I
N A
- Base load current I
L
- Base load current I
H
- Max. output current I
max
Type rating
- Based on I
(50 Hz 690 V)
L
- Based on I
(50 Hz 690 V)
H
- Based on I
(50 Hz 500 V)
L
- Based on I
(50 Hz 500 V)
H
- Based on I
(60 Hz 575 V)
L
- Based on I
(60 Hz 575 V)
H
DC-link current
-Rated current I
when fed via
N DC
- Basic/Smart Line Module
- Active Line Module
Base load current I
when fed via
L DC
- Basic/Smart Line Module
- Active Line Module
Base load current I
when fed via
H DC
- Basic/Smart Line Module
- Active Line Module
Supply voltages
- DC-link voltage
- Electronic power supply
- Output voltage
Rated pulse frequency
- Max. pulse frequency without derating
- Max. pulse frequency with derating
Max. ambient temperature
- Without derating
- With derating
DC-link capacitance
Current consumption
- Electronics current consumption (24 VDC)
- Fan supply, at 2 AC 690 V, 50/60 Hz
Power loss, max.
3)
- at 50 Hz 690 V
- at 60 Hz 575 V
Cooling air requirement
Sound pressure level
L
(1 m) at 50/60 Hz
pA
Connections
- DC-link connection
- Motor connection
- PE connection PE1
- PE connection PE2
Max. conductor cross-sections
- DC-link connection (DCP, DCN)
- Motor connection (U2, V2, W2)
- PE connection PE1
- PE connection PE2
Motor cable length, max.
- shielded
- unshielded
Air-cooled chassis power units
Equipment Manual, 06/2020, 6SL3097-5AE00-0BP3
6SL3320–
A
A
A
A
kW
1)
kW
1)
kW
1)
kW
1)
HP
2)
HP
2)
A
A
A
A
A
A
V
DC
V
DC
V
ACrms
kHz
kHz
kHz
° C
° C
μF
A
A
kW
kW
m
/s
3
dB(A)
mm²
mm²
mm²
mm²
4)
m
m
1TG34–1AA3 1TG34–7AA3 1TG35–8AA3 1TG37–4AA3
410
465
400
452
367
416
600
678
400
450
315
400
250
315
200
250
400
450
350
450
492
558
443
502
479
544
431
489
437
496
394
446
675 ... 1035
24 (20.4 ... 28.8)
0 ... 0.75 x DC link voltage
1.25
1.25
1.25
1.25
7.5
7.5
40
40
55
55
7400
7400
1.0
1.0
2.1 / 3.1
2.1 / 3.1
6.13
6.80
5.71
6.32
0.78
0.78
70 / 73
70 / 73
4 x M10
4 x M10
2 x M12
2 x M12
M12
M12
2 x M12
2 x M12
Busbar
Busbar
4 x 240
4 x 240
1 x 240
1 x 240
2 x 240
2 x 240
300
300
450
450
Motor Modules
6.1 Motor Modules Chassis
575
735
560
710
514
657
840
1065
560
710
450
630
400
500
315
450
600
700
500
700
690
882
621
794
672
859
605
774
614
784
552
706
1.25
1.25
1.25
1.25
7.5
7.5
40
40
55
55
7400
11100
1.0
1.25
2.1 / 3.1
3.1 / 4.6
10.3
10.9
9.7
10.0
0.78
1.08
70 / 73
71 / 73
4 x M10
4 x M10
2 x M12
3 x M12
M12
M12
2 x M12
3 x M12
Busbar
Busbar
4 x 240
6 x 240
1 x 240
1 x 240
2 x 240
3 x 240
300
300
450
450
283

Advertisement