Installing The Braking Module In A Basic Line Module, Frame Size Fb - Siemens SINAMICS S120 Manual

Air-cooled chassis power units
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

7.1.4.5

Installing the Braking Module in a Basic Line Module, frame size FB

Figure 7-12
Installing the Braking Module
The steps for the installation procedure are numbered in accordance with the diagram.
1. Unscrew the three screws of the blanking plate.
Remove the plate.
2. Insert the Braking Module where the cover used to be and secure it using the three screws
(from step 1).
3. Attach the adapter bar to the DCNA using a nut, so that the busbar cannot be twisted. For
this purpose, a small bolt is attached to the adapter bar, which must be located on the lower
side of the DCNA connection.
4. Secure the connecting cable to the DC link with two screws (Braking Module connection)
and two nuts (DC-link connection).
Air-cooled chassis power units
Equipment Manual, 06/2020, 6SL3097-5AE00-0BP3
Installing the Braking Module in a Basic Line Module, frame size FB
DC link components
7.1 Braking Module
347

Advertisement

Table of Contents
loading

Table of Contents