Motor Modules
6.2 Motor Modules Chassis-2
The accessory pack of the Motor Module includes 3 shield clamps for cable diameters
3 ...6 mm and 6 ...8 mm.
Use the respective shielding clamps corresponding to the cables to be shielded.
Attach shield clip
Figure 6-24
316
Installed signal cable with strain relief and shielding
Snap in shield clip
Air-cooled chassis power units
Equipment Manual, 06/2020, 6SL3097-5AE00-0BP3