Table 8- 30
Technical data of the dv/dt filter plus voltage peak limiter, 3 AC 380 ... 480 V, Part 2
Article number
Matching Motor Module
Chassis-2
Type rating of the Motor
Module
I
thmax
Degree of protection
dv/dt reactor
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
Connections
- To the Motor Module
- Load
- PE
Max. permissible cable
length between dv/dt reac-
tor and motor
Dimensions
Width
Height
Depth
Weight, approx.
Voltage peak limiter
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
Connections
- To the dv/dt reactor
- DC
- PE
Dimensions
Width
Height
Depth
Weight, approx.
Two dv/dt reactors are required for these dv/dt filters. The technical data provided applies to one dv/dt reactor.
1)
Note
Cable lengths for versions with two dv/dt reactors
For versions with 2 dv/dt reactors, the cable lengths specified in the table do not change.
Air-cooled chassis power units
Equipment Manual, 06/2020, 6SL3097-5AE00-0BP3
6SL3000-
6SL3321-
kW
A
kW
kW
kW
m
mm
mm
mm
kg
kW
kW
kW
mm
mm
mm
kg
8.3 dv/dt filter plus Voltage Peak Limiter
2DE38-4AA0
1TE36-6AA0
315
840
IP00
1.106
1.115
1.226
M12
M12
M6
300 (shielded)
450 (unshielded)
460
385
312
149
0.077
0.072
0.066
M8
M8
M8
309
1312.5
400
48
Motor-side power components
2DE41-4AA0
1TE37-4AA0 / 1TE38-1AA0
1TE38-8AA0 / 1TE41-0AA0
1TE41-1AA0 / 1TE41-2AA0
1TE41-3AA0 / 1TE41-5AA0
355 / 400 / 450 / 500 / 560 / 630 / 710 /
800
1405
IP00
1.111
1.154
1.23
2 x M12
2 x M12
M6
445
385
312
158
0.134
0.125
0.114
M10
M10
M8
309
1312.5
400
72
1)
393