Device Data Of The 230 V Devices; Overview Of The 230 V Devices - KEB COMBIVERT F6 Series Instructions For Use Manual

Installation f6 housing 2
Hide thumbs Also See for COMBIVERT F6 Series:
Table of Contents

Advertisement

DeVIce DATA OF THe 230 V DeVIceS

3.2 Device data of the 230 V devices

3.2.1 Overview of the 230 V devices

The technical data are for 2/4-pole standard motors. With other pole numbers the drive
converter must be dimensioned onto the rated motor current. Contact KEB for special or
medium frequency motors.
Device size
Housing
Rated apparent output power
Max. rated motor power
Rated input voltage
Input voltage range
Mains phases
Mains frequency
Rated input current
@ U
= 230V
N
Rated input current
@ U
= 240V
N
Output voltage
Output frequency
Output phases
Rated output current
@ U
= 230 V
N
Rated output current
@ U
= 240 V
N
Rated output overload (60 s)
Software current limit
Overcurrent
Rated switching frequency
Max. switching frequency
Power dissipation at rated operation
Overload current over time
Maximum current 0Hz / 50Hz at f
Maximum current 0Hz / 50Hz atf
Maximum current 0Hz / 50Hz at f
Maximum current 0Hz / 50Hz at f
Max. braking current
Min. braking resistor value
S
/ kVA
out
P
/ kW
mot
U
/ V
N
U
/ V
in
f
/ Hz
N
/ A
I
in
I
/ A
in_UL
U
/ V
out
f
/ Hz
2)
out
I
/ A
N
/ A
I
N_UL
I
/ %
1) 5)
60s
I
/ %
lim
I
/ %
1)
OC
/ kHz
f
SN
f
/ kHz
4)
S_max
P
/ W
3)
D
/ %
I
OL
= 2 kHz
I
/ %
S
Max_Out
= 4 kHz
I
/ %
S
Max_Out
= 8 kHz
I
/ %
S
Max_Out
= 16 kHz
I
/ %
S
Max_Out
I
/ A
B_max
R
/ Ω
B_min
10
12
2
4.4
7
2.2
4
230 (UL: 240)
170...264
3
50 / 60 ±2
16.5
22
16.5
22
0...U
0...599
3
11
17.5
11
17.5
150
180
216
8
4
16
102
=> „Overload characteristic (OL) for 230 V devices"
216 / 216
200 / 216
173 / 216
127 / 216
21.5
19
continued on the next page
13
14
9.6
13
5.5
7.5
30
41.5
30
41.5
in
24
33
24
33
150
180
4
4
tbd
tbd
12
29

Advertisement

Table of Contents
loading

Table of Contents