OPerATING cONDITIONS

3.1.2 Mechanical ambient conditions

Storage
Vibration limits
Shock limit values
Transport
Vibration limits
Shock limit values
Operation
Vibration limits
Shock limit values
Table 3:
Mechanical ambient conditions
*Not tested

3.1.3 chemical / mechanical active substances

Storage
Gases
Contamination
Solids
Transport
Gases
Contamination
Solids
Operation
Gases
Contamination
Solids
Table 4:
Chemical / mechanical active substances
Standard
class
EN 60721-3-1
1M2
EN 60721-3-1
1M2
Standard
class
EN 60721-3-2
2M1
EN 60721-3-2
2M1
Standard
class
EN 60721-3-3
3M4
EN 61800-5-1
EN 60721-3-3
3M4
Standard
class
1C2
EN 60721-3-1
1S2
Standard
class
2C2
EN 60721-3-2
2S2
Standard
class
3C2
EN 60721-3-3
3S2
Descriptions
Vibration amplitude 1.5 mm (2...9 Hz)
Acceleration amplitude 5 m/s² (9...200 Hz)
40 m/s²; 22 ms
Descriptions
Vibration amplitude 3.5 mm (2...9 Hz)
Acceleration amplitude 10 m/s² (9...200 Hz)
(Acceleration amplitude 15 m/s² (200...500 Hz))*
100 m/s²; 11 ms
Descriptions
Vibration amplitude 3.0 mm (2...9 Hz)
Acceleration amplitude 10 m/s² (9...200 Hz)
Vibration amplitude 0.075 mm (10...57 Hz)
Acceleration amplitude 10 m/s² (57...150 Hz)
100 m/s²; 11 ms
Descriptions
Descriptions
Descriptions