cONNecTION OF THe POWer UNIT
4.2.5 connection of the motor
4.2.5.1 Wiring of the motor
Legend
①
KEB COMBIVERT
Apply motor cable, shielding on both sides over a large surface on the bare metallic frame or mounting
②
plate (remove paint if necessary)
③
Three-phase motor
④
Temperature monitoring (optional) =>
Figure 22:
Wiring of the motor
4.2.5.2 Terminal block X1A motor connection
Name
Function
U
V
Motor connection
W
Figure 23:
Terminal block X1A motor connection
68
➀
➁
Control
P A/K
9
5
X1C
10
6
U
U
X1A
V
V
W
W
Instructions for use „Control circuit"
cross-section for terminal connection
Flexible line with wire-end ferrule with
plastic collars 2.5...10 mm²
For 2 conductors 0.5mm...1.5mm²
For UL flexible line without wire-end
ferrule AWG 26...6
➂
④
Tightening
torque
1.5 Nm
13 Ib inch
Max. number
of conductors
For IEC: 2
For UL: 1