r2198
CO/BO: Monitoring word 2
Monitoring word 2, which indicates the state of monitor functions. Each bit represents one
monitor function.
Unit: -
Min: -
Bit fields:
Bit00
Bit01
Bit02
Bit03
Bit04
Bit05
Bit06
Bit07
Bit08
Bit09
Bit10
Bit11
Bit12
Note:
Bit12 (belt failure trip) will only be reset after fault quitting and applying a new ON command.
T, rated is calculated from the machine data during quick commissioning.
P2200[2]
BI: Enable PID controller
The PID mode allows the user to enable / disable the PID controller. Setting to 1 enables the
PID controller.
Unit: -
Min: 0:0
Index:
P2200[0]: VSD in "Auto" mode
Dependency:
Setting 1 does not disable the normal ramp times set in P1120 and P1121. However the normal frequency setpoints are
disabled. A PID setpoint change will be limited by P2257 and P2258 (PID setpoint ramp)
Following an OFF1 or OFF3 command, however, the VSD frequency will ramp down to zero using the ramp time set in
P1121 (P1135 for OFF3).
Note:
The PID setpoint source is selected using P2253. The PID setpoint and the PID feedback signal are interpreted as [%]
values (not [Hz]). The output of the PID controller is displayed as [%] and then normalized into [Hz] through P2000
(reference frequency) when PID is enabled. In level 3, the PID controller source enable can also come from the digital
inputs in settings 722.0 to 722.2 for DIN1 to DIN3 or from any other BiCo source.
The minimum and maximum motor frequencies (P1080 and P1082) as well as the skip frequencies (P1091 to P1094)
remain active on the VSD output. However, enabling skip frequencies with PID control can produce instabilities.
P2201
Fixed PID setpoint 1 through 15
through
P2215
Defines fixed PID setpoint 1.
Unit: % Min: -200.00
Details:
Defines fixed PID setpoint 1. In addition, you can set any of the digital input parameters to fixed PID setpoint via the
digital inputs (P0701 - P0706).
There are 3 selection modes for the PID fixed setpoint:
1.
Direct selection (P0701=15 or P0702=15, etc.)
In this mode of operation, 1 digital input selects one PID fixed setpoint
2.
Direct selection with ON command (P0701=16 or P0702=16, etc.)
Description as for 1) except that this type of selection delivers an ON command concurrent with any setpoint selection.
3.
Binary Coded Decimal selection with ON command (P0701 - P0704=17)
Using this method to select the PID fixed setpoint allows you to choose up to 16 different PID setpoints.
The setpoints are selected according to the following table:
Note: An ON command is only generated if all 6 digital inputs (P0701 - P0704) are set to 17.
P2201
P2202
P2203
P2204
P2205
P2206
P2207
P2208
P2209
P2210
P2211
88 / 100
Siemens
Building Technologies
Act. Freq. r0024
<=
Act. freq. r0024
<=
Act. freq. r0024
>
Act. freq. r0024
>
Act. freq. r0024
>=
Act. freq. r0024
<=
Act. freq. r0024
>=
Act. freq. r0024
==
Reserved
Act. unfilt. Vdc
<
Act. unfilt. Vdc
>
No load condition
Def: -
Reserved
Reserved
Reserved
Reserved
| n,set | < 3 Hz
n,set > 0
Motor blocked
Motor stalled
Reserved
|T,act| > T,rated & setpoint reached
|T,act| > T,rated value
Belt failure warning
Belt failure trip
Def: 0:0
Def: See note below
OFF
FF1
FF2
FF3
FF4
FF5
FF6
FF7
FF8
FF9
FF10
FF11
Commissioning Guide
10 Parameterization
P1080
0
NO, 1
P2155
0
NO, 1
P2155
0
NO, 1
zero
0
NO, 1
setp.
0
NO, 1
P2167
0
NO, 1
P1082
0
NO, 1
setp.
0
NO, 1
800 V
0
NO, 1
800 V
0
NO, 1
0
NO, 1
Max: -
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
0
NO, 1
Max: 4000:0
P2200[1]: VSD in "Hand" mode
Max: 200.00
DIN4
DIN3
Inactive
Inactive
Inactive
Inactive
Inactive
Inactive
Inactive
Inactive
Inactive
Active
Inactive
Active
Inactive
Active
Inactive
Active
Active
Inactive
Active
Inactive
Active
Inactive
Active
Inactive
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
DIN2
Inactive
Inactive
Active
Active
Inactive
Inactive
Active
Active
Inactive
Inactive
Active
Active
Level 3
Level 2
Level 3
DIN1
Inactive
Active
Inactive
Active
Inactive
Active
Inactive
Active
Inactive
Active
Inactive
Active