1. "With parameter change" means that the value is actually adopted as the P0350 parameter setting and applied to the
control as well as being shown in the read-only parameters below
2. "Without parameter change" means that the value is only displayed, i.e. shown for checking purposes in the read-
only parameter r1912 (identified stator resistance). The value is not applied to the control
r1912[3]
Identified stator resistance
Displays measured stator resistance value (line to line) in [Ohm].
Unit: Ohm
Min: -
Index:
r1912[0]: U phase
Note:
This value is measured using P1910=1 or 2 , i.e., identification of all parameters with / without change.
P2000
Reference frequency
Full-scale frequency setting used by serial link (corresponds to 4000H), analog I/O and P/D
controller.
Unit: Hz
Min: 1.00
P2001
Reference voltage
Full-scale output voltage (i.e. 100% ) used over serial link (corresponds to 4000H).
Unit: V
Min: 10
Example
P2001=230 specifies that 4000H received via USS denotes 230 V
P2002
Reference current
Full-scale output current used over serial link (corresponds to 4000H).
Unit: A Min: 0.10
r2004
Reference power
Full-scale reference power used over the serial link (corresponds to 4000H).
Unit: -
Min: -
P2009[2]
USS normalization
Min: 0
Settings:
0=Disabled
Index:
P2009[0]: Serial interface COM link
Note:
If enabled, the main setpoint (word 2 in PZD) is not interpreted as 100%=4000H, but as "absolute" instead
(e.g. 4000H=16384 means 163.84 Hz).
PZD: Process data
P2010[2]
USS Baud rate
Sets Baud rate for USS communication.
Unit: -
Min: 4
Settings:
4=2400 Baud
5=4800 Baud
6=9600 Baud
Index:
P2010[0]: Serial interface COM link
P2011[2]
USS address
Sets a unique address for the VSD.
Unit: -
Min: 0
Index:
P2011[0]: Serial interface COM link
Note:
You can connect up to another 30 VSDs via RS-485 (i.e. 31 VSDs in total) and control them with the USS serial bus protocol.
P2014[2]
USS telegram off time
Defines a time T_off after which a fault will be generated (F0070) if no telegram is received via
the USS channels.
Unit: ms
Min: 0
Index:
P2014[0]: Serial interface COM link
Note:
By default (time set to 0), no fault is generated (i.e. watchdog disabled).
P2040
CB telegram off time
Defines time after which a fault will be generated (F0070) if no telegram is received via the link (SOL).
Unit: ms
Min: 0
Dependency:
Setting 0=watchdog disabled
P2041[5]
CB parameter
Configures a communication board (CB)
Unit: -
Min: 0
Index:
P2041[0]: CB parameter 0
P2041[1]: CB parameter 1
Note:
See relevant communication board Manual for protocol definition and appropriate settings.
r2050[8]
CO: PZD from CB
Displays PZD (process data) received from the communication board (CB).
Unit: -
Min: -
Index:
r2050[0]: Received word 0
r2050[1]: Received word 1
r2050[2]: Received word 2
Note:
The control words can be viewed as bit parameters r2032 and r2033.
P2051[8]
CI: PZD to CB
Connects PZD to CB. This parameter allows the user to define the source of status words and
actual values for the reply PZD. (PZD: Process data).
Siemens
Building Technologies
Def: -
r1912[1]: V phase
Def: 50.00
Def: 1000
Def: 0.10
Def: -
Def: 0
Def: 6
7=19200 Baud
8=38400 Baud
Def: 0
Def: 0
Def: 20
Def: 0
P2041[2]: CB parameter 2
P2041[3]: CB parameter 3
Def: -
r2050[3]: Received word 3
r2050[4]: Received word 4
r2050[5]: Received word 5
Commissioning Guide
10 Parameterization
Max: -
r1912[2]: W phase
Max: 650.00
Max: 2000
Max: 10000.00
Max: -
Max: 1
1=Enabled
P2009[1]: Serial interface BOP link
Max: 12
9=57600 Baud
10=76800 Baud
P2010[1]: Serial interface BOP link
Max: 31
P2011[1]: Serial interface BOP link
Max: 65535
P2014[1]: Serial interface BOP link
Max: 65535
Max: 65535
P2041[4]: CB parameter 4
Max: -
r2050[6]: Received word 6
r2050[7]: Received word 7
Level 3
Level 2
Level 3
Level 3
Level 3
Level 3
Level 3
11= 93750 Baud
12=115200 Baud
Level 3
Level 3
Level 3
Level 3
Level 3
Level 3