Unit: -
Min: 0:0
Settings:
Status word 1=52.
CO/BO: Act. status word 1 (see r0052).
Actual value 1=21 VSD output frequency (see r0021).
Other BICO settings are possible.
Index:
P2051[0]: Transmitted word 0
P2051[1]: Transmitted word 1
P2051[2]: Transmitted word 2
r2053[5]
CB identification
Displays identification data of the communication board (CB). The different CB types (r2053[0])
are given in the Enum declaration.
Unit: -
Min: -
Settings:
0=No CB option board
1=PROFIBUS DP
Index:
r2053[0]: CB type (PROFIBUS=1)
r2053[1]: Firmware version
r2053[2]: Firmware version detail
r2054[7]
CB diagnostics
Displays diagnostic information of the communication board (CB).
Unit: -
Min: -
Index:
r2054[0]: CB diagnostics 0
r2054[1]: CB diagnostics 1
r2054[2]: CB diagnostics 2
P2100[3]
Alarm number selection
Selects up to 3 faults or warnings for non-default reactions.
Unit: -
Min: 0
Example:
If you want F0005 to perform an OFF3 instead of an OFF2, set P2100[0]=5, then select the desired response in
P2101[0] (in this case, set P2101[0]=3).
Note:
All fault codes have a default response to OFF2. Some fault codes caused by hardware trips (e.g. overcurrent) cannot
be changed from the default responses.
P2101[3]
Stop reaction value
Sets VSD stop reaction values for fault selected by P2100 (alarm number stop reaction).
This indexed parameter specifies the special response to the faults / warnings defined in
P2100 indices 0 to 2.
Unit: -
Min: 0
Settings:
0=No reaction, no display
1=OFF1 stop reaction
Note:
Settings 0 - 3 are only available for fault codes.
Settings 0 and 4 are only available for warnings.
Index 0 (P2101) refers to fault / warning in index 0 (P2100).
r2110[4]
Warning number
Displays warning information.
Unit: -
Min: -
Details
A maximum of 2 active warnings (indices 0 and 1) and 2 historical warnings (indices 2 and 3) may be viewed
Index:
r2110[0]: Recent warnings --, warning 1
r2110[1]: Recent warnings --, warning 2
Note:
The keypad will flash while a warning is active. The LEDs indicate the warning status in this case.
If an AOP is in use, the display will show number and text of the active warning.
Indices 0 and 1 are not stored.
P2111
Total number of warnings
Displays number of warning (up to 4) since last reset. Set to 0 to reset the warning history.
Unit: -
Min: 0
r2114[2]
Run time counter
Displays run time counter. It is the total time the VSD has been powered up. Every time you do
power cycle, it will save the value; then, restore it and the counter carries on ticking.
Unit: -
Min: -
Settings:
r2114[0]: = System time, seconds, upper word
Details:
See r0948 (fault time)
r2115[3]
AOP real time clock
Displays AOP real time.
Unit: -
Min: 0
Index:
P2115[0]: Real time, seconds+minutes
Details:
See r0948 (fault time)
P2155
Threshold frequency f_1
Sets a threshold for comparing actual speed or frequency to threshold values f_1.
Unit: Hz
Min: 0.00
Details
This threshold controls status bits 04 and 05 in status word 2 (r0053) and bits 01 and 02 in r2197.
P2156
Delay time of threshold freq f_1
Sets delay time prior to threshold frequency f_1 comparison (P2155).
Unit: ms
Min: 0
86 / 100
Siemens
Building Technologies
Def: 52:0
P2051[3]: Transmitted word 3
P2051[4]: Transmitted word 4
P2051[5]: Transmitted word 5
Def: -
Def: -
r2054[3]: CB diagnostics 3
r2054[4]: CB diagnostics 4
Def: 0
Def: 0
2=OFF2 stop reaction
3=OFF3 stop reaction
Def: -
Def: 0
Def: -
Def: 0
P2115[1]: Real time, hours+days
Def: 30.00
Def: 10
Commissioning Guide
10 Parameterization
Max: 4000:0
P2051[6]: Transmitted word 6
P2051[7]: Transmitted word 7
Max: -
2=DeviceNet
56 not defined
r2053[3]: Firmware date (year)
r2053[4]: Firmware date (day / month)
Max: -
r2054[5]: CB diagnostics 5
r2054[6]: CB diagnostics 6
Max: 65535
Max: 5
4=No reaction warning only
5=Goto fixed frequency 15
Max: -
r2110[2]: Recent warnings -1, warning 3
r2110[3]: Recent warnings -1, warning 4
Max: 4
Max: -
r2114[1]: = System time, seconds, lower word
Max: 65535
P2115[2]: Real time, month+year
Max: 650.00
Max: 10000