8.4 SETUP AND OPERATING INSTRUCTIONS

To prevent damage to the unit, do not program the Output voltage and
8.4.1

Setting up the Power Supply for 0-5V/0-10V Isolated Programming and Monitoring

Perform the following procedure to configure the power supply:
1. Press the power supply AC Input power switch to the OFF position.
2. Connect a wire jumper between J1-8 and J1-12 (refer to Table 4-4).
3. Set DIP-switch SW1-1 to the UP position for Output voltage external programming and SW1-2 to the UP
position for Output current limit external programming.
4. Set SW1-3 to select the Programming Voltage Range: DOWN = 0-5V, UP = 0-10V.
5. Set SW1-4 to select the Monitoring Voltage Range: DOWN = 0-5V, UP = 0-10V.
6. Ensure that SW1-7 and SW1-8 are in the DOWN position.
7. Connect the programming sources to the mating plug of the Isolated Programming connector. Observe for
correct polarity of the voltage source.
8. Set the programming sources to the desired levels. Turn ON the power supply by pressing the AC Input
power switch to ON and then pressing the front panel display OUT button.
8.4.2

Setting up the Power Supply for 4-20mA Isolated Programming and Monitoring

Perform the following procedure to configure the power supply:
1. Press the power supply AC Input power switch to the OFF position.
2. Connect a wire jumper between J1-8 and J1-12 (refer to Table 4-4).
3. Set DIP-switch SW1-1 to the UP position for Output voltage external programming and SW1-2 to the UP
position for Output current limit external programming.
4. Set SW1-3 to the UP position.
5. Set SW1-4 to the UP position.
6. Ensure that SW1-7 and SW1-8 are in the DOWN position.
7. Connect the programming source to the mating plug of the Isolated Programming connector. Observe for
correct polarity of the voltage source.
8. Set the programming sources to the desired levels. Turn ON the power supply by pressing the AC Input
power switch to ON and then pressing the front panel display OUT button.programming sources to the
desired levels and turn the power supply ON.
SW1-3 and SW1-4 must be in the UP position for operation with the 4-20mA
CAUTION
Output current to higher than the power supply ratings.
J1-8 and J1-12 must be connected together with a jumper.
J1-8 and J1-12 must be connected together with a jumper.
Isolated Programming and Monitoring Interface.
83-517-000 Rev. A
NOTE
NOTE
NOTE
74