CHAPTER 6 REMOTE ANALOG PROGRAMMING

6.1 INTRODUCTION

The rear panel connector J1 allows the user to program the power supply Output voltage and Output current
limit with an analog device. J1 also provides monitoring signals for Output voltage and Output current. The
programming range and monitoring signals range can be selected between 0 - 5V and 0 - 10V using the setup
DIP-switch SW1. When the power supply is in the Remote Analog programming mode, the serial communication
port (J3) is active and can be used to read the power supply operating parameters.
COM (J1-12), VPGM_RTN (J1-22) and IPGM_RTN (J1-23) terminals of J1 connect
internally to the -Vout potential (-V). Do not connect these terminals to any potential

6.2 LOCAL/REMOTE ANALOG CONTROL

J1-9 (Figure 4-2, Item 5) accepts a TTL signal or Open-Short contact (referenced to J1-12) to select between
Local or Remote Analog programming of the Output voltage and Output current limit.
In Local mode, the Output voltage and Output current limit can be programmed via the front panel VOLTAGE
and CURRENT encoders or via the J3 RS-232/RS-485 port. In Remote Analog mode, the Output voltage and
Output current limit can be programmed by analog voltage or by programming resistors via J1-9 and J1-10 (refer
to Sections 6.4 and 6.5 for additional details). Refer to Table 6-1 for Local/Remote Analog control (J1-8)
function and Setup DIP-switch SW1-1, -2 settings.

6.3 LOCAL/REMOTE ANALOG INDICATION

J1-21 (Figure 4-2, Item 5) is an open-collector output that indicates if the power supply is in Local mode (front
panel) or in Remote Analog mode. To use this function, connect a pull-up resistor to a voltage source of 30VDC
maximum. Choose the pull-up resistor so that the sink current will be less than 5mADC when the output is in a
low state. Refer to table 6-2 for J1-21 function.
TTL "0" Or Short
TTL "1" or Open
other than -Vout (-V), as it may damage the power supply.
SW1-1, -2 setting
J1-8 Function
DOWN (default)
UP
Table 6-1: Local/Remote Analog Control Function
J1-8
SW1-1
DOWN
DOWN
UP
UP
DOWN or UP
Table 6-2: Local/Remote Analog Indication
83-517-000 Rev. A
CAUTION
Output V/I Setting
No effect
"0" or Short
Remote Analog
"1" or Open
SW1-2
DOWN
UP
DOWN
UP
DOWN or UP
54
Local
Local
J1-21 Signal
OPEN
0.0 ~ 0.6V
0.0 ~ 0.6V
0.0 ~ 0.6V
Open-collector