8.4 SETUP AND OPERATING INSTRUCTIONS

CAUTION
To prevent damage to the unit, do not program
the output voltage and current to higher then the
power supply rating.

8.4.1 Setting up the power supply for 0-5/0-10V Isolated Programming and Monitoring

Perform the following procedure to configure the power supply:
1. Turn the power supply AC power switch to Off.
2. Connect a short between J1-8 and J1-12 (refer to Table 4-4).
3. Set Setup switch SW1-1 to its UP position for Output Voltage external programming
and SW1-2 to its UP position for Output Current limit external programming.
4. Set SW1 position 3 to select the programming voltage range: Down=0-5V, Up=0-10V.
5. Set SW1 position 4 to select the monitoring range: Down=0-5V, Up=0-10V.
6. Ensure that SW1 positions 7 and 8 are in the their down position.
7. Connect the programming sources to the mating plug of the Isolated Programming
connector. Observe for correct polarity of the voltage source.
NOTE
J1-8 and J1-12 must be shorted together with a jumper.
8. Set the programming sources to the desired levels and turn the power supply ON.

8.4.2 Setting up the power supply for 4-20mA Isolated Programming and Monitoring

Perform the following procedure to configure the power supply:
1. Turn the power supply AC power switch to Off.
2. Connect a short between J1-8 and J1-12 (refer to Table 4-4).
3.Set setup switch SW1-1 to its UP position for Output Voltage external programming and
SW1-2 to its UP position for Output Current limit external programming.
4. Set SW1 position 3 to it's Up position.
5. Set SW1 position 4 to it's Up position.
6. Ensure that SW1 positions 7 and 8 are in their Down position.
7. Connect the programming source to the mating plug of the Isolated Programming
connector. Observe for correct polarity of the voltage source.
NOTE
J1-8 and J1-12 must be shorted together with a jumper.
8. Set the programming sources to the desired levels and turn the power supply ON.
NOTE
SW1 position 3 and 4 must be in their Up position for
operation with 4-20mA Isolated Programming and
Monitoring.
Um das Gerät vor Schäden zu schützen,
programmieren Sie keine Spannungs- oder
Stromwerte, die über den maximalen
Nennwerten liegen.
J -8 und J - 2 müssen über einen Jumper miteinander
1
1 1
verbunden werden.
J -8 und J - 2 müssen über einen Jumper miteinander
1
1 1
verbunden werden.
Für die isolierte Programmierung und Überwachung
mittels 4-20mA-Signalen müssen die Schalter 3 und 4
von SW1 in der oberen Position stehen.
65
65
VORSICHT
HINWEIS
HINWEIS
HINWEIS

Advertisement

Table of Contents
loading

Table of Contents