CHAPTER 3 INSTALLATION

3.1 GENERAL

This Chapter contains instructions for initial inspection, preparation for use and repackaging for shipment.
Connection to PC, setting the communication port and linking Genesys
Chapter 7.
The Genesys
Location (RAL). Access to Hazardous parts (rear side of the power supply)
Genesys
operation of other instruments. If your equipment is susceptible to magnetic
To avoid electric shock hazard, do not insert conductive parts through the

3.2 PREPARATION FOR USE

In order to be operational the power supply must be connected to an appropriate AC source. The AC source
voltage should be within the power supply specification. Do not apply power before reading Section 3.6 and 3.7.
Table 3-1 below, describes the basic setup procedure. Follow the instructions in Table 3-1 in the sequence given
to prepare the power supply for use.
Step #
Item
1
Inspection
2
Installation
3
AC source
4
Test
5
Load connection
6
Default setting

3.3 INITIAL INSPECTION

Prior to shipment this power supply was inspected and found free of mechanical or electrical defects. Upon
unpacking of the power supply, inspect for any damage, which may have occurred in transit.
The inspection should confirm that there is no exterior damage to the power supply such as broken knobs or
connectors and that the front panel and meter's faces are not scratched or cracked. Keep all packing material
until the inspection has been completed. If damage is detected, file a claim with carrier immediately and notify
the TDK Lambda Americas, Inc. Sales or Authorized Service Facility near you.

3.4 RACK MOUNTING

TM
power supply series is designed to fit in a standard 19" equipment rack.
The Genesys
3.4.1

To Install the Power Supply in a Rack:

1. Use the front panel rack-mount brackets to install the power supply in the rack.
2. Use a support bar to provide adequate support for the rear of the power supply. Do not obstruct the air
exhaust at the rear panel of the unit.
WARNING
TM
series is intended only for installation in Restricted Access
shall be prevented after installation.
TM
power supplies generate magnetic fields, which might affect the
fields, do not position it adjacent to the power supply.
WARNING
front panel slits.
Initial physical inspection of the power supply
Installing the power supply,
Ensuring adequate ventilation.
AC source requirements
Connecting the power supply to the AC source
Turn-on checkout procedure.
Wire size selection. Local/Remote sensing. Single
or multiple loads.
The power supply setting at shipment.
Table 3-1: Basic Setup Procedure
83-517-000 Rev. A
TM
NOTE
Description
22
power supplies are described in
Reference
Section 3.3
Section 3.4
Section 3.5
Section 3.6
Section 3.7
Section 3.8
Section 3.9
Section 7.2.1

Advertisement

Table of Contents
loading

Table of Contents