Led Status Indicators - Leuze electronic BCL548i Manual

Table of Contents

Advertisement

Display and control panel
Status display of the USB interface
USB
The BCL
MS
An external parameter memory is properly connected to the USB interface of the
BCL 548i.
Read result
The read bar code information is displayed.
Link states
Displays the link states (LNK0 and LNK1) of the PROFINET-IO interface.
• LNK0: physical connection to the HOST / BUS IN port
• LNK1: physical connection to the BUS OUT port
8.2.2

LED status indicators

PWR LED
off
flashes green
green continuous light Device ok
orange continuous light Service mode
flashes red
red continuous light
90
548i
is connected to a PC via the USB interface.
Device OFF
- no supply voltage
Device ok, initialization phase
- no bar code reading possible
- voltage connected
- self test running
- initialization running
- bar code reading possible
- self test successfully finished
- device monitoring active
- bar code reading possible
- configuration via the USB service interface
- configuration via the display
- no data on the host interface
Device ok, warning set
- bar code reading possible
- temporary operating fault
Device error / parameter enable
- no bar code reading possible
BCL
548i
Leuze electronic