CDVI DIGIWAY Plus Manual
CDVI DIGIWAY Plus Manual

CDVI DIGIWAY Plus Manual

Inwards and outwards door operator, door automation
Hide thumbs Also See for DIGIWAY Plus:

Advertisement

2
YEAR
WARRANTY
*
DIGIWAY Plus
Inwards and Outwards Door Operator,
Door Automation
EN

Advertisement

Table of Contents
loading

Summary of Contents for CDVI DIGIWAY Plus

  • Page 1 YEAR WARRANTY DIGIWAY Plus Inwards and Outwards Door Operator, Door Automation...
  • Page 2: Table Of Contents

    DIGIWAY Plus Inward or Outward Door Operator Summary Summary page page General safety instructions and precautions General safety instructions and precautions ....Machinery Directive Machinery Directive ....Instructions of use Instructions of use ....Declaration of the Manufacturer Declaration of the Manufacturer...
  • Page 3 DIGIWAY Plus Inward or Outward Door Operator IMPORTANT SAFETY IMPORTANT SAFETY PRECAUTIONS PRECAUTIONS The present document contains important precautions for safe use and operation. The present document contains important precautions for safe use and operation. Read the instructions Read the instructions carefully carefully before commencing the installation.
  • Page 4: Machinery Directive

    DIGIWAY Plus Inward or Outward Door Operator The manufacturer declines all liability for damage caused by outdoor assembly without The manufacturer declines all liability for damage caused by outdoor assembly without adequate protection. adequate protection. This product cannot be installed in places with an explosive atmosphere or in the This product cannot be installed in places with an explosive atmosphere or in the presence of flflammable fumes or gases.
  • Page 5: Instructions Of Use

    ( according to Directive 2006/42/CE 2006/42/CE, Annex II part B ) , Annex II part B ) The Manufacturer The Manufacturer CDVI WIRELESS SPA - CDVI Group CDVI WIRELESS SPA - CDVI Group Via Piave,23 Via Piave,23 31020 S.Pietro di Feletto (TV) 31020 S.Pietro di Feletto (TV)
  • Page 6 DIGIWAY Plus Inward or Outward Door Operator 1] IDENTIFYING THE PRODUCT AND ITS PARTS 1] IDENTIFYING THE PRODUCT AND ITS PARTS DIGIWAY type DWPx102xx is an indoor operator for swing doors, with integrated electronic DIGIWAY type DWPx102xx is an indoor operator for swing doors, with integrated electronic controller and radio receiver.
  • Page 7: Accessories

    DIGIWAY Plus Inward or Outward Door Operator Accessories Accessories Description F-code Kit articulated Kit articulated DWKBA F0543000030 Kit sliding arm Kit sliding arm DWKBS F0543000031 Kit universal Kit universal DWKBU F0543000122 Extension 55 Extension 55 DWSE F0543000033 Extension 30 Extension 30...
  • Page 8 DIGIWAY Plus Inward or Outward Door Operator Mounting diagram Mounting diagram Cover lift point Cover lift point Screws for plugs SX8 Screws for plugs SX8 M6x14 M6x14 Plugs SX8 Plugs SX8 M6x14 M6x14 Washer Washer M6x14 M6x14 Sliding arm Sliding arm...
  • Page 9: Technical Specifications

    DIGIWAY Plus Inward or Outward Door Operator Technical specifications Technical specifications General specifications General specifications Power Power 230 Vac - 50 Hz 15 Nm 230 Vac - 50 Hz 15 Nm Motor torque Motor torque 15 Nm 15 Nm Max power...
  • Page 10 DIGIWAY Plus Inward or Outward Door Operator Electronic card specifications Electronic card specifications Operating modes: Operating modes: Automatic ( I ) - Door free ( 0 ) - Door always open (II) Automatic ( I ) - Door free ( 0 ) - Door always open (II)
  • Page 11: Sliding Arm Version

    DIGIWAY Plus Inward or Outward Door Operator 2] INSTALLATION 2] INSTALLATION Important: Check the integrity of the door that is to be automated, verifiying Important: Check the integrity of the door that is to be automated, verifiying the operation in both directions is smooth without any friction from the closed the operation in both directions is smooth without any friction from the closed to open position and the open to closed position.
  • Page 12: Articulated Arm Version

    DIGIWAY Plus Inward or Outward Door Operator The Sliding Arm is designed for pull applications, inward opening doors. The Sliding Arm is designed for pull applications, inward opening doors. Using the dimensions of the motor and the template provided (see inside of the Using the dimensions of the motor and the template provided (see inside of the box sleeve) locate the fixing positions and cable holes;...
  • Page 13 DIGIWAY Plus Inward or Outward Door Operator Speed Power Parameter Description (mm) (mm) Door hinge – door bracket distance Door hinge – door bracket distance Door hinge – motor axis distance Door hinge – motor axis distance A - B A - B Motor axis –...
  • Page 14: Wiring Diagram

    DIGIWAY Plus Inward or Outward Door Operator Wiring diagram Wiring diagram 6 x 0.8 mm 6 x 0.8 mm FTC-S [ Stop ] FTC-S [ Stop ] 6 x 0.8 mm 6 x 0.8 mm FTC [ Re-open ] FTC [ Re-open ]...
  • Page 15: Electrical Connections

    DIGIWAY Plus Inward or Outward Door Operator Jumper for external switch exclusion Jumper for external switch exclusion The external mode switch on the end cap can be isolated to prevent misuse or for use The external mode switch on the end cap can be isolated to prevent misuse or for use with a remote switching device such as the DWSP-KS keyswitch.
  • Page 16 If devices type ESPE (photocells) are used, they must be monitored by the drive system. DIGIWAY Plus is equipped with output test signals (Test1, C, Test2) that check the DIGIWAY Plus is equipped with output test signals (Test1, C, Test2) that check the photocells’...
  • Page 17 DIGIWAY Plus Inward or Outward Door Operator 5 6 7 5 6 7 T1 C T2 T1 C T2 20 21 20 21 Power (+) Power (+) Power (-) Power (-) Relay C Relay C STOP Photocells (FTC-S) STOP Photocells (FTC-S)
  • Page 18: Battery

    DIGIWAY Plus Inward or Outward Door Operator Electronic card LED’s Electronic card LED’s LED ON LED OFF Fire voltage OK Fire voltage ABSENT NC contact stop photocells closed NC contact stop photocells open NC contact re-open photocells closed NC contact re-open photocells open...
  • Page 19: Step Ii: Configuration

    GETTING STARTED GETTING STARTED DIGIWAY Plus is equipped with a 2x16 characters LCD Display and by a 5-key keyboard. DIGIWAY Plus is equipped with a 2x16 characters LCD Display and by a 5-key keyboard. The operating configuration can be set navigating through several menus. The menu The operating configuration can be set navigating through several menus.
  • Page 20: Step Iii: Door Calibration

    DIGIWAY Plus Inward or Outward Door Operator The set-up of the operator can be divided into 5 steps The set-up of the operator can be divided into 5 steps: : • • STEP I STEP I : INITIAL SETUP : INITIAL SETUP (preliminary actions) (preliminary actions) •...
  • Page 21 DIGIWAY Plus Inward or Outward Door Operator STEP II: CONFIGURATION Step II allows the set up of all the basic parameters of the operator depending on Step II allows the set up of all the basic parameters of the operator depending on the door type that is being automated.
  • Page 22 STEP III: DOOR CALIBRATION [SINGLE LEAF] DIGIWAY Plus is equipped with an innovative software which fits the internal parameters DIGIWAY Plus is equipped with an innovative software which fits the internal parameters to the door characteristics.
  • Page 23 DIGIWAY Plus Inward or Outward Door Operator Press OK: the door begins 5 cycles of Closing ... opening and closing until asking for Measure 1/5... SAVE Warning: whilst the Digiway is going trough its Tm= XX,X V= XX 5 learning cycles, it can be...
  • Page 24 DIGIWAY Plus Inward or Outward Door Operator Main Description Values NOTES Functions At the end of the door calibration the systems sets au- tomatically the max open speed at a special value. By Sets the maximum speed increasing this value, the total open time can reduce -...
  • Page 25 STEP V: ADVANCED SETTINGS DIGIWAY Plus is equipped with many further parameters (all adjustable) to better DIGIWAY Plus is equipped with many further parameters (all adjustable) to better suit any type of installation. From the main menu select suit any type of installation.
  • Page 26 DIGIWAY Plus Inward or Outward Door Operator Advanced Setting Wind Stop Torque 5) 5) |||||||||||||||||....10% Wind Stop Torque It is possible to adjust the torque of the motor when the wind stop function is enabled. This allows It is possible to adjust the torque of the motor when the wind stop function is enabled. This allows you to change the value of the force applied by the door relative to the wind pressure.
  • Page 27 DIGIWAY Plus Inward or Outward Door Operator Advanced Setting Enable / Disable Ex Power Close When enabled, adds one more When enabled, adds one more CLOSING CLOSING pulse after the regular CLOSING cycle to compensate pulse after the regular CLOSING cycle to compensate possible friction or door imbalance.
  • Page 28 DIGIWAY Plus Inward or Outward Door Operator Approach speed Advanced Setting Approach speed |||||||||||||||||...... It is possible to change the approach speed as the door approaches the final close point. This is It is possible to change the approach speed as the door approaches the final close point. This is useful if the door senses an obstacle or finishes short of a strike.
  • Page 29: Disabled Persons Access Settings

    DIGIWAY Plus Inward or Outward Door Operator STOP / Advanced Setting LOW ENERGY Test FTC-S Fail In case of malfunction of the safety photocells FTC-S, it’s possible to set the operating mode: In case of malfunction of the safety photocells FTC-S, it’s possible to set the operating mode:...
  • Page 30: Remote Controls Management

    DIGIWAY Plus Inward or Outward Door Operator Remote controls management Remote controls management The unit is equipped with a superhetherodyne AM receiver with The unit is equipped with a superhetherodyne AM receiver with Keeloq® Hopping code Keeloq® Hopping code security protocol.
  • Page 31 DIGIWAY Plus Inward or Outward Door Operator SERVICE COUNTER MENU MAIN COUNTER SERVICE THRESHOLD SERVICE PASSWORD THRESHOLD 1111 0500 SERVICE CONFIRM SERVICE PASSWORD RESET COUNTER 1111 RESET COUNTER? NEW PASSWORD SERVICE PASSWORD CHANGE PASSWORD 1111 0000 CONF PASSWORD 0000 NOTES NOTES (1) Partial counter value;...
  • Page 32 DIGIWAY Plus Inward or Outward Door Operator LEGEND LEGEND DISPLAY EXPERT MODE DISPLAY EXPERT MODE M / S M / S 1,2,3,4,5,f 1,2,3,4,5,f Master / Master / Obstacle Obstacle restart for restart for Opening Opening Closing Closing Opening Opening Opening...
  • Page 33 DIGIWAY Plus Inward or Outward Door Operator 4] DOUBLE DOOR CONFIGURATION 4] DOUBLE DOOR CONFIGURATION The double door configuration applies to both the types DWPD102X (not available in The double door configuration applies to both the types DWPD102X (not available in the UK) and DWPS102X.
  • Page 34 DIGIWAY Plus Inward or Outward Door Operator 3. Motor fixing 3. Motor fixing Fix each motor with the 6 screws M6x14 provided. Fix each motor with the 6 screws M6x14 provided. 6 x M6x14 screws for fixing to the back-plate...
  • Page 35 DIGIWAY Plus Inward or Outward Door Operator 6. Mechanical check 6. Mechanical check • • Move the side switches in position 0 and check the fluency of the motion both in Move the side switches in position 0 and check the fluency of the motion both in opening and in closing.
  • Page 36 DIGIWAY Plus Inward or Outward Door Operator 2) Connect the RADARs, the Day/Night switch to the unit identified as MASTER (if Connect the RADARs, the Day/Night switch to the unit identified as MASTER (if required) required) 3) The contacts NC of the safety devices ( photocells ) can be connected in 2 ways: The contacts NC of the safety devices ( photocells ) can be connected in 2 ways: •...
  • Page 37 DIGIWAY Plus Inward or Outward Door Operator Follow the Door CALIBRATION procedure, corresponding to STEP III, described on page Follow the Door CALIBRATION procedure, corresponding to STEP III, described on page 22 of this manual, up to the end. The door remains OPEN 22 of this manual, up to the end.
  • Page 38 DIGIWAY Plus Inward or Outward Door Operator 5] INSTRUCTIONS FOR USE 5] INSTRUCTIONS FOR USE If the door is If the door is working working properly the led LP is STABLE GREEN properly the led LP is STABLE GREEN HOW TO OPEN THE DOOR...
  • Page 39 6] MAINTENANCE 6] MAINTENANCE An automatic door, installed with the DIGIWAY Plus operator, needs periodic checks (at An automatic door, installed with the DIGIWAY Plus operator, needs periodic checks (at least every 12 months) as listed in the following points: least every 12 months) as listed in the following points: 1) Check the door balancing and the functionality of the hinges;...
  • Page 40 Type Description DWMBT F0543000179 BLUETOOTH PLUG-IN MODULE FOR DIGIWAY PLUS Installing the Bluetooth module on a DIGIWAY Plus Installing the Bluetooth module on a DIGIWAY Plus 1) Remove the cover 2) Power off the unit! 3) Disconnect the batter cable!
  • Page 41 (*) The correct functionality of the first dot on the left of the App that monitors the “FIRE” led is guaranted if the firmware revision installed on Digiway is Digiway Plus : > 2.8a. For all previous firmware revisions, the management of the “Fire” LED is not implemented. The dot of the App does not indicate the correct status of the fire function.
  • Page 42 DIGIWAY Plus Inward or Outward Door Operator Select the target unit. Input the password: All Select the target The first time you will modules come preset DIGIWAY. The App will be asked to enter the with password “00000”. show the corresponding password.
  • Page 43 DIGIWAY Plus Inward or Outward Door Operator Access to hidden menu Access to the inner menu (only upon specific need, and followed by factory assistance) is granted by pressing the screen of the smartphone in 3 points, according to a specific...
  • Page 44 DIGIWAY Plus Inward or Outward Door Operator Installing Manufacturer: Installing Manufacturer: (Name of the company who installed the Automatic Door Operator) (Name of the company who installed the Automatic Door Operator) Identification: Identification: (Identity of the door that has been automated such as door location or serial...
  • Page 45 DIGIWAY Plus Inward or Outward Door Operator Hazard Description Installation notes and/or actions taken to eliminate or reduce the risk Impact Impact Crushing Crushing Shearing Shearing Wedging Wedging Conveying Conveying Cutting Cutting Hooking Hooking Service Service Date: Date: Operator name:...
  • Page 46 DIGIWAY Plus Inward or Outward Door Operator NOTES NOTES...
  • Page 47 DIGIWAY Plus Inward or Outward Door Operator NOTES NOTES Manufactured by Manufactured by CDVI Wireless S.p.A. CDVI Wireless S.p.A. Via Piave, 23 Via Piave, 23 31020 S.Pietro di Feletto (TV) 31020 S.Pietro di Feletto (TV) ITALY ITALY...
  • Page 48 Tel: +39 0438 450860 www.erone.com CDVI MAROC +212 (0) 5 22 48 09 40 www.cdvi.ma CDVI NORDICS [SWEDEN - DENMARK - NORWAY - FINLAND] +46 (0) 31 760 19 30 www.cdvi.se CDVI UK [UNITED KINGDOM - IRELAND] +44 (0) 1628 531300 www.cdvi.co.uk...

Table of Contents