EN
Follow the Door CALIBRATION procedure, corresponding to STEP III, described on page
Follow the Door CALIBRATION procedure, corresponding to STEP III, described on page
7
22 of this manual, up to the end. The door remains OPEN. .
22 of this manual, up to the end. The door remains OPEN
Set the ENGAGE POSITION: This is the point (in case of overlapping doors) where the 2
Set the ENGAGE POSITION: This is the point (in case of overlapping doors) where the 2
8
leaves are free to open and close without any interference.
leaves are free to open and close without any interference.
Set the value at 25 (factory setting) for both the leaves. In case you need increase the
Set the value at 25 (factory setting) for both the leaves. In case you need increase the
9
value, note that greater values delay the closing of the Master leaf which starts and stops
value, note that greater values delay the closing of the Master leaf which starts and stops
waiting for the Slave.
waiting for the Slave.
Enter the CONFIGURATION menu of the SLAVE
Enter the CONFIGURATION menu of the
10
NUM. DOORS
NUM. DOORS
2 DOORS OVERLAP
2 DOORS OVERLAP
DOOR TYPE
DOOR TYPE
Enter the CONFIGURATION menu of the MASTER
Enter the CONFIGURATION menu of the
11
NUM. DOORS
NUM. DOORS
2 DOORS OVERLAP
2 DOORS OVERLAP
DOOR TYPE
DOOR TYPE
12
Move both the external switches to position "I": the 2 doors close very slowly. Test the
Move both the external switches to position "I": the 2 doors close very slowly. Test the
function by pressing either the OK button of the transmitter congifured to the MASTER
function by pressing either the OK button of the transmitter congifured to the MASTER
or down key of the keypad or the exit button connected to terminal 15 and 16 of the
or down key of the keypad or the exit button connected to terminal 15 and 16 of the
MASTER.
MASTER.
The procedure is over.
The procedure is over.
SLAVE
SLAVE
15 16
15 16
Inward or Outward Door Operator
Door Calibration
Door Engage Pos.
SLAVE unit and set the following parameters:
= TWO DOORS
= TWO DOORS
= ENABLE (only if there is door leaf overlap)
= ENABLE
(only if there is door leaf overlap)
= SLAVE
= SLAVE
MASTER unit and set the following parameters:
= TWO DOORS
= TWO DOORS
= ENABLE (only if there is door leaf overlap)
= ENABLE
(only if there is door leaf overlap)
= MASTER
= MASTER
MASTER
MASTER
15 16
15 16
DIGIWAY Plus
Door Engage Pos.
025
|||||||||||||||||...................
unit and set the following parameters:
unit and set the following parameters:
HOW TO OPEN ONE OR BOTH DOORS
HOW TO OPEN ONE OR BOTH DOORS
OPEN BOTH THE DOORS
OPEN BOTH THE DOORS
OPEN ONLY THE MASTER
OPEN ONLY THE MASTER
37