Main
Functions
Sets the maximum speed
Open Speed
reached by the door
during opening.
Sets the maximum speed
Close Speed
reached by the door
during closing.
Pause time - this is the
time remains open be-
Pause Time
fore automatically closing
again
Pause Time
Extended Pause time
ext
Open
Max torque of the door
Torque
during opening.
Close
Max torque of the door
Torque
during closing
Velocity of the door: ra-
pidity of the door to reach
Velocity
the max speed set, and to
mantain this value along
all its travel.
Sets the obstacles
O.D. Type
detection criteria
O.D.
Sets the reaction time
Reactivity
against an obstacle
24
DIGIWAY Plus
Inward or Outward Door Operator
Description
Values
100%
100%
1 - 99
SEC.
1 - 99
SEC.
100%
100%
100%
v v
Vmax
Vmax
Velocity = 0%
Velocity = 0%
B1 & B2
B3
B4
B5
B3+B4
B3+B4+B5
0,1 - 5 sec.
At the end of the door calibration the systems sets au-
tomatically the max open speed at a special value. By
0 -
increasing this value, the total open time can reduce -
be aware that in order to respect the end
opening point, the door may slow down before reaching
the max speed.
At the end of the door calibration the systems sets
automatically the max close speed at a special value.
0 -
By increasing this value, the total close time can reduce
- be aware that in order to respect the end closing
point, the door may slow down before reaching the max
speed.
The preset factory value is 10 sec.
When the Disabled mode is enabled, if the door is
opened through a command at the inputs 15-16, it will
re-close after the Ext Pause time. The Pause time for
the remaining commands ( radar, push&go, remote con-
trols) the pause time remains the regular one.
The max opening torque is set automatically by the sys-
0 -
tem at the end of the door calibration to the max value
(100 %). In the case of very light or sensitive doors, it
may be necessary to decrease this value.
The max closing torque is set automatically by the
system, at the end of the door calibration, to the max
0 -
value ( 100 %). Decrease this value in case of very
light or sensitive doors, or to respect the regulations for
disabled access.
The default value for this parameter is 70%. The more
this value, the less is the total travel time, because the
0 -
door maintains a high value of speed for a longer time.
Values too high for this parameter can cause "door
bounce", especially for heavy doors (see motion dia-
gram).
Velocity = 100%
Velocity = 100%
t t
t t
2 2
1 1
B1 and B2 sono are basic criteria always active
B3 = intervenes after the speed decreases under 2/3
of the max speed, calculated during the calibration.
B4 = intervenes if the current consumed exceeds
175% of the current consumed during the preset.
B5 = intervenes if the door is manually pushed during
the closing
Bf = obstacle detected by the slave leaf in double door
Bf
configuration
Use the UP or DOWN keys to adjust this time : the
higher the value,
the longer will be the contact of the door against the
obstacle (less sensitive). Default value = 0,1 Sec.
NOTES
Motion
Motion
diagram
diagram
t t
t t
3 3
EN
Need help?
Do you have a question about the DIGIWAY Plus and is the answer not in the manual?
Questions and answers