DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors Table of Contents Table of Contents page page IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS GENERAL SAFETY INSTRUCTIONS AND PRECAUTIONS GENERAL SAFETY INSTRUCTIONS AND PRECAUTIONS ..............
2006/42/CE Annex II part B) Annex II part B) user must not be carried out by children without supervision. The Manufacturer The Manufacturer CDVI WIRELESS SPA - CDVI Group CDVI WIRELESS SPA - CDVI Group Via Piave,23 Via Piave,23 Machinery Directive 31020 S.Pietro di Feletto (TV)
F0543000219 only only F0543000095 DWPS102UCD DIGIWAY PLUS operator 230VAC for inswing or outswing doors - universal DIGIWAY PLUS operator 230VAC for inswing or outswing doors - universal F0543000180 DWPS102ABT DIGIWAY PLUS operator 230VAC for inswing doors - articulated arm w/ Bluetooth module...
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors Mounting diagram Technical specifications General features General features Cover lift point Cover lift point Screws for plugs SX 8...
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors Electronic card specifications Electronic card specifications 2] INSTALLATION Operating modes: Automatic ( I ) - Door free ( 0 ) - Door always open (II)
Fully automated operator for inward or outward opening doors Mechanical installation: articulated arm version The following tables show the recommended mounting dimensions for the DIGIWAY Plus referencing to B, L1, H and C shown in the previous diagrams. The Articulated Arm is designed for push applications and outward opening doors.
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors Wiring diagram Full diagram 6 x 0.8 mm 6 x 0.8 mm FTC-S [ FTC-S [ Stop Stop 6 x 0.8 mm...
The DIGIWAY Plus is equipped with output test signals (Test1, C, Test2) that check the photocells’ status before any motion. (see “Advanced Settings” under point 15)-18) to match the signal test to the sensor type) The system switches the photocell off and back on within a few mS to detect a change of the safety signal on terminals 5-6 and 6-7.
Getting started LED ON LED OFF DIGIWAY Plus is equipped with a 2x16 character LCD display and a 5-key keyboard. The operating configuration can be set navigating through several menus. The menu has a tree Fire voltage OK Fire voltage ABSENT structure with a main menu and different sub-menus.
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors The setup of the operator can be divided into The setup of the operator can be divided into 4 steps...
The CONFIGURATION submenu allows you to set up of all the basic parameters of the operator DIGIWAY Plus has an innovative software which adapts the internal paremeters to the depending on the door type that is being automated. It consists of 18 parameters. Each characteristics of the door.
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors Calibration Completion PART III: MAIN FUNCTIONS At the end of auto-calibration, the door is operational. However, for the door to be fully functional a couple of full complete cycles must be carried out.
Page 14
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors Gestion des obstacles Zero Mode It is possible to set the mode used by the system to calculate the “door closed” position:...
Dynamic pause is a function which automatically adjusts the programmed pause time, preventing too DIGIWAY Plus is equipped with many additional parameters (all adjustable) to better suit any many close attempts of the door in high traffic situations. When enabled, this function increases the many close attempts of the door in high traffic situations.
Page 16
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors Advanced Setting Ex Close Torque Advanced Setting Obst. detection % Ex Close Torque 50 % |||||||||||||||||....Obst. detection % |||||||||||||||||......
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors Remote controls management Advanced Setting FTC Test Mode FTC Test Mode Active HIGH/Active LOW The unit is equipped with a superhetherodyne AM receiver with KeeLoq® hopping code security The test signal for the safety photocells (FTC/ FTC-S) can be set to operate as “Active HIGH”...
Page 18
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors Menu Service (4) Resets the partial counter value: It has to be reset after the maintenance intervention and resets the main LED to solid GREEN.
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors 4] DOUBLE DOOR CONFIGURATION Legend Display in Expert Mode Legend Display in Expert Mode M / S M / S...
Page 20
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors Part II : Electrical Connections 3. Motor fixing The range of motors for the double door is described in the following table: Fix each motor with the 6 M6x14 screws provided.
Page 21
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors 2) Connect the radars and the Day/Night switch to the unit identified as MASTER (if required) Set the ENGAGE POSITION: This is the point (in case of overlapping doors) where the 2 leaves are free to open and close without any interference.
If the door is working properly the LP LED is stable green. If the door is working properly the LP LED is stable green. An automatic door, installed with the DIGIWAY Plus operator, needs periodic checks (at least every 12 months) as listed in the following points: How to open the door 1) Check the door balancing and the functionality of the hinge.
(*) The correct functionality of the first dot on the left of the App that monitors the “FIRE” LED is guaranteed if the 3) Disconnect the battery cable! firmware revision installed on the door operator is DIGIWAY Plus : > 2.8a. For all previous firmware revisions, the 4) Plug in the polarised module connector onto the white 6-poles connector of the management of the “Fire”...
Page 24
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors You will be asked to You will be asked to The app will start Press OK for 4 sec. to...
Page 25
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors Installing Manufacturer: Installing Manufacturer: (Name of the company who installed the Automatic Door Operator) (Name of the company who installed the Automatic Door Operator)
Page 26
DIGIWAY PLUS DIGIWAY PLUS Fully automated operator for inward or outward opening doors Fully automated operator for inward or outward opening doors Notes Hazard Description Installation notes and/or actions taken to eliminate or reduce the risk ....................................... Impact Impact .......................................
Need help?
Do you have a question about the DIGIWAY PLUS and is the answer not in the manual?
Questions and answers