Once the operator installed, check that friction or unbalancing don't cause the systematic
Once the operator installed, check that friction or unbalancing don't cause the systematic
obstacle detection. Select the obstacle detection criteria which best fits to the type of
obstacle detection. Select the obstacle detection criteria which best fits to the type of
installation.
installation.
The closing cycle after an obstacle detection is executed at low speed.
The closing cycle after an obstacle detection is executed at low speed.
ATTENTION:
ATTENTION: Reactivity values higher than 0,1 Sec, allow to overcome to possible
Reactivity values higher than 0,1 Sec, allow to overcome to possible
frictions but extend the reaction time and so can generate higher impact of the door on
frictions but extend the reaction time and so can generate higher impact of the door on
the obstacle.
the obstacle.
DIGIWAY Plus is equipped with many further parameters (all adjustable) to better
DIGIWAY Plus is equipped with many further parameters (all adjustable) to better
suit any type of installation. From the main menu select ADVANCED SET to enter this
suit any type of installation. From the main menu select
submenu, which allows more adjustments.
submenu, which allows more adjustments.
Advanced Setting
1) 1)
Electrolock Time
It is possible to set the electrolock release time from 0,1 to 40 sec. depending on the lock/door type.
It is possible to set the electrolock release time from 0,1 to 40 sec. depending on the lock/door type.
Press the UP or DOWN buttons to increase or decrease the pause time and confirm with OK.
Press the UP or DOWN buttons to increase or decrease the pause time and confirm with OK.
Default value = 0,5 Sec
Default value = 0,5 Sec
Advanced Setting
2) 2)
Opening Jolt Time
The opening jolt, when enabled, is a short closing motion before the operator begins opening - this
The opening jolt, when enabled, is a short closing motion before the operator begins opening - this
relieves pressure of "side-load" for some locking devices. You can adjust this time from 0,1 to 40 sec.
relieves pressure of "side-load" for some locking devices. You can adjust this time from
depending on the type of electrolock and door. Press the UP or DOWN buttons to increase or decrease
depending on the type of electrolock and door.
the time and confirm with OK.
the time and confirm with OK.
Default value = 0,5 Sec
Default value = 0,5 Sec
Advanced Setting
3) 3)
Open Jolt Torque
It is possible to adjust the torque of the motor during the opening jolt pulse. This is adjusted
It is possible to adjust the torque of the motor during the opening jolt pulse. This is adjusted
depending on the mechanical resistance of the door. Press the
depending on the mechanical resistance of the door. Press the UP or DOWN buttons to increase or
decrease the value and confirm with OK.
decrease the value and confirm with OK.
Default value =
Default value = 20%
Advanced Setting
4) 4)
Open Delay
It is possible to add a short delay to the door motion to allow the electrolock bolt to exit completely
It is possible to add a short delay to the door motion to allow the electrolock bolt to exit completely
from its keeper, ensuring the door is fully unlocked. This can be useful when using motorised locks.
from its keeper, ensuring the door is fully unlocked. This can be useful when using motorised locks.
The open delay is set by pressing
The open delay is set by pressing UP or DOWN buttons to increase or decrease
and confirm with OK. .
and confirm with OK
Default value = 0,5 Sec
Default value = 0,5 Sec
Inward or Outward Door Operator
STEP V: ADVANCED SETTINGS
Electrolock Time
|||||||||||||||||......0,5 SEC.
Opening Jolt Time
|||||||||||||..........0,5 SEC.
Open Jolt Torque
|||||||||||||||||............20%
20%
Open Delay Time
0,5 SEC.
|||||||||||||||||............
UP or DOWN buttons to increase or decrease from
DIGIWAY Plus
ADVANCED SET to enter this
Press the UP or DOWN buttons to increase or decrease
UP or DOWN buttons to increase or
LOCK
LOCK
Delay
Delay
MOTOR
MOTOR
START
START
0,1 to 40 sec.
from 0,1 to 40 sec
0,1 to 40 sec